Skip to content

What are you looking for?


You may also like

ABB AO895 3BSC690087R1 S800 I/O Intrinsic Safety Analog Output Module with HARTABB AO895 3BSC690087R1 S800 I/O Intrinsic Safety Analog Output Module with HARTABB AO895 3BSC690087R1 S800 I/O Intrinsic Safety Analog Output Module with HART
ABB AO895 3BSC690087R1 S800 I/O Intrinsic Safety Analog Output Module with HART
ABB AO895 3BSC690087R1 S800 I/O Intrinsic Safety Analog Output Module with HART
ABB AO895 3BSC690087R1 S800 I/O Intrinsic Safety Analog Output Module with HART

ABB AO895 3BSC690087R1 S800 I/O Intrinsic Safety Analog Output Module with HART


Only 10 left - Selling fast

PRODUCT SKU : AO895 3BSC690087R1

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The ABB AO895 is an 8-channel analog output module for the S800 I/O system, designed to control field devices in hazardous areas. With built-in energy-limiting barriers, it supports direct connection to intrinsically safe actuators and positioners without external isolators. The module also features HART pass-through communication for digital configuration and maintenance via the AC 800M controller, enhancing safety and process efficiency.

Specifications

  • Manufacturer: ABB

  • Country of Origin: Switzerland

  • Model Number: AO895

  • Order Number: 3BSC690087R1

  • Product Type: Intrinsically Safe Analog Output

  • Output Channels: 8

  • Current Range: 4 to 20 mA

  • Digital Communication: HART pass-through supported

  • Hazardous Area Suitability: Designed for field devices in Zone 0, 1, or 2

  • Resolution: 12-bit

  • Weight: 0.3 kg

Features

  • Integrated Safety Barriers: Features internal circuitry that limits energy to hazardous areas, significantly reducing installation footprint and wiring costs.

  • HART Asset Management: Supports bidirectional digital data exchange for remote monitoring and recalibration of smart actuators.

  • Redundant Configuration: Capable of being utilized in redundant pairs to ensure maximum system availability for critical process control loops.

  • Output Supervision: Continuous read-back functionality allows the module to monitor the actual output current and detect open circuits or high resistance.

  • Advanced Isolation: Provides high-level galvanic isolation between the system backplane and the field circuits to eliminate ground loop noise.

  • Modular Maintenance: Compatible with S800 Module Termination Units (MTUs) and supports hot-swapping to ensure zero-downtime hardware replacement.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more