Skip to content

What are you looking for?


You may also like

ABB AI895 3BSC690086R1 S800 I/O Intrinsic Safety Analog Input Module with HARTABB AI895 3BSC690086R1 S800 I/O Intrinsic Safety Analog Input Module with HARTABB AI895 3BSC690086R1 S800 I/O Intrinsic Safety Analog Input Module with HART
ABB AI895 3BSC690086R1 S800 I/O Intrinsic Safety Analog Input Module with HART
ABB AI895 3BSC690086R1 S800 I/O Intrinsic Safety Analog Input Module with HART
ABB AI895 3BSC690086R1 S800 I/O Intrinsic Safety Analog Input Module with HART

ABB AI895 3BSC690086R1 S800 I/O Intrinsic Safety Analog Input Module with HART


Only 10 left - Selling fast

PRODUCT SKU : AI895 3BSC690086R1

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The ABB AI895 is a high-performance 8-channel analog input module designed for the S800 I/O platform. This unit is specifically engineered to interface with 4-20 mA transmitters located in hazardous environments by incorporating internal energy-limiting barriers. By removing the need for external isolation hardware, the 3BSC690086R1 optimizes cabinet space and reduces installation costs. It supports full HART digital communication pass-through, allowing for advanced device management and remote diagnostics of smart field instruments within the System 800xA architecture.

Specifications

  • Manufacturer: ABB

  • Country of Origin: Switzerland

  • Model Number: AI895

  • Order Number: 3BSC690086R1

  • Product Type: Intrinsically Safe Analog Input

  • Number of Channels: 8

  • Input Signal Range: 4 to 20 mA

  • A/D Resolution: 12-bit

  • HART Support: Bi-directional HART communication

  • Hazardous Area Suitability: Designed for connection to devices in Zone 0, 1, and 2

  • Weight: 0.3 kg

Features

  • Built-in Safety Barriers: Provides direct connectivity to field instruments in explosive atmospheres without requiring additional galvanic isolators.

  • HART Digital Integration: Facilitates seamless access to smart instrument data, including secondary variables and device health status.

  • High-Density Monitoring: Eight differential channels provide efficient use of space for complex process monitoring networks.

  • Channel Isolation: Engineered with robust galvanic isolation to prevent ground loop interference and ensure signal purity.

  • System Diagnostics: Continuously monitors for field wiring faults such as open circuits or short circuits, reporting status directly to the controller.

  • Redundant Application: Compatible with redundant configuration schemes to enhance system availability and process uptime.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more