Skip to content

What are you looking for?


You may also like

AAI841-H50 | Yokogawa | Non-Isolated Analog I/O Module (8-Input/8-Output)AAI841-H50 | Yokogawa | Non-Isolated Analog I/O Module (8-Input/8-Output)AAI841-H50 | Yokogawa | Non-Isolated Analog I/O Module (8-Input/8-Output)
AAI841-H50 | Yokogawa | Non-Isolated Analog I/O Module (8-Input/8-Output)
AAI841-H50 | Yokogawa | Non-Isolated Analog I/O Module (8-Input/8-Output)
AAI841-H50 | Yokogawa | Non-Isolated Analog I/O Module (8-Input/8-Output)

AAI841-H50 | Yokogawa | Non-Isolated Analog I/O Module (8-Input/8-Output)


Only 10 left - Selling fast

PRODUCT SKU : AAI841-H50

PRODUCT TYPE : Analog I/O Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Technical Overview

The AAI841-H50 is a high-performance analog mixing module designed for the Yokogawa CENTUM VP integrated control system. This module provides a compact footprint for process automation by integrating 8 input channels and 8 output channels into a single unit. It is engineered for high-speed data acquisition with a 10 ms update cycle, making it ideal for dynamic control loops where latency must be minimized.

As a non-isolated module, the AAI841-H50 shares a common ground, which optimizes space and cost for environments where external signal isolation is already managed or not required. The built-in transmitter power supply ensures that field instruments receive stable voltage even under full load.

Detailed Specifications

  • Module Identification: AAI841-H50

  • I/O Configuration: 8-channel current input / 8-channel current output

  • Isolation: Non-isolated (Common ground)

  • Signal Range: 4 to 20 mA DC

  • Input Accuracy: ±16 µA (High-precision sensing)

  • Data Refresh Rate: 10 ms

  • Input Impedance: 250 Ω

  • Maximum Input Current: 25 mA

  • Transmitter Power Supply: 14.8 V DC (at 20 mA) to 26.4 V DC (at 0 mA)

  • Output Allowable Load Resistance: 0 to 600 Ω

  • External Interface Options: Pressure clamp terminals, KS cable, or MIL connector cable

  • Power Consumption: Max 450 mA (5 V DC)

  • Physical Weight: Approximately 1.3 kg

Module Connectivity and Integration

The AAI841-H50 supports multiple wiring methodologies to suit various cabinet architectures. For rapid deployment, the MIL connector or KS cable interface allows for "plug-and-play" integration with terminal boards. For traditional point-to-point field wiring, the pressure clamp terminal provides a secure, vibration-resistant connection.

Frequently Asked Questions

  • Can this module power 2-wire transmitters?

    Yes, it includes an integrated power supply that delivers at least 14.8 V at a full 20 mA load.

  • What is the impact of it being non-isolated?

    Non-isolated modules require a shared reference potential. If your field signals have significant ground loops or voltage offsets, an external signal isolator or an isolated Yokogawa module variant should be used.

  • Does the 10 ms update period apply to both I and O?

    Yes, the high-speed data update period is synchronized across the input and output processing cycles of the module.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial PC vs. Commercial PC: Selecting the Right Hardware for Automation

Industrial PC vs. Commercial PC: Selecting the Right Hardware for Automation

In the demanding world of factory automation, selecting the correct computing platform is critical for system reliability. While commercial PCs power our daily lives, they often fail when subjected to the harsh realities of the production floor. Understanding the fundamental differences between an Industrial PC (IPC) and a standard office PC helps engineers optimize control systems for longevity and performance.

Read more
Core Components of Programmable Logic Controllers (PLC) in Industrial Automation

Core Components of Programmable Logic Controllers (PLC) in Industrial Automation

A Programmable Logic Controller (PLC) serves as the digital backbone of modern factory automation. Whether you are managing complex assembly lines or simple process loops, understanding the hardware and software architecture of a PLC is essential for any control systems engineer.

Read more
PLC vs. PC: Navigating the Architectural Differences in Industrial Automation

PLC vs. PC: Navigating the Architectural Differences in Industrial Automation

In the realm of factory automation, professionals often debate the roles of Programmable Logic Controllers (PLCs) and Personal Computers (PCs). While both devices share fundamental computing architectures—including a processor, memory, and an operating system—their design philosophies diverge significantly. Understanding these distinctions is critical for selecting the right hardware for your industrial control systems.

Read more