Product Overview

The Honeywell MC-TAIH14 (Part Number: 51305887-150) functions as a High-Level Analog Input Field Termination Assembly (FTA) designed for high-density signal acquisition. This module interfaces 16 field-side 4-20mA signals directly with the Honeywell control environment, providing integrated HART communication pass-through for smart instrument diagnostics. We supply this unit in 100% Brand New, original factory condition, ensuring your mission-critical process loops benefit from the highest available signal fidelity and zero-hour operational life.

Technical Specifications

Feature Specification Details
Model Number MC-TAIH14
Part Number 51305887-150
Analog Input Channels 16 Channels
Input Range 4–20 mA DC
Input Accuracy 0.05% of Full Scale
Isolation Rating 500 V Galvanic Isolation
Digital Communication HART Protocol Supported
Operating Temperature -20°C to 60°C
Physical Dimensions 120mm x 70mm x 110mm
Power Consumption 5W at 24VDC

Engineering Advantages

  • High-Precision Data Acquisition: The 0.05% input accuracy ensures micro-level precision for flow, pressure, and temperature loops. This ultra-low margin of error eliminates the data drift commonly found in lower-tier I/O interfaces.

  • Smart Instrument Integration: The module supports bi-directional HART communication. This allows maintenance teams to access field device diagnostics, configuration data, and secondary variables without disconnecting wiring or using external handheld communicators.

  • Superior Noise Mitigation: 500V galvanic isolation shields the internal control bus from field-side electrical surges and common-mode noise. This protection prevents ground loops and safeguards the central processor from catastrophic electrical failure in lightning-prone or high-EMI environments.

  • Extended Thermal Performance: The hardware maintains linear accuracy across a broad temperature range (-20°C to 60°C). This thermal resilience permits installation in non-climate-controlled marshalling cabinets and remote instrument buildings.

  • Space-Optimized Footprint: The compact 120mm profile allows for high-density mounting on standard I/O carriers. This simplifies cable management and reduces the total number of marshalling cabinets required for large-scale facility upgrades.

FAQs

  • Does this module support both active and passive 4-20mA loops? The MC-TAIH14 interfaces with standard 4-20mA transmitters. Ensure your field wiring matches the specific powering requirements (loop-powered vs. self-powered) as defined by your Honeywell I/O processor configuration.

  • Is this a genuine Honeywell original part? Yes. We deliver the MC-TAIH14 in 100% Brand New condition, sourced directly through authorized channels to guarantee authenticity, full factory specifications, and original packaging.

  • How does the HART support function within the DCS? The module provides a transparent data path for the HART digital signal superimposed on the 4-20mA analog loop. This enables your asset management software to communicate directly with smart field devices for real-time health monitoring.

  • What are the grounding requirements during installation? Properly terminate the shield wires at the FTA grounding bar to maximize the effectiveness of the 500V isolation. This practice ensures that electromagnetic interference does not compromise the high 0.05% accuracy rating.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more