Skip to content

What are you looking for?


You may also like

Honeywell Experion PKS Series 8 | 8C-TDOLA1 | Digital Output ModuleHoneywell Experion PKS Series 8 | 8C-TDOLA1 | Digital Output ModuleHoneywell Experion PKS Series 8 | 8C-TDOLA1 | Digital Output Module
Honeywell Experion PKS Series 8 | 8C-TDOLA1 | Digital Output Module
Honeywell Experion PKS Series 8 | 8C-TDOLA1 | Digital Output Module
Honeywell Experion PKS Series 8 | 8C-TDOLA1 | Digital Output Module

Honeywell Experion PKS Series 8 | 8C-TDOLA1 | Digital Output Module


Only 10 left - Selling fast

PRODUCT SKU : 8C-TDOLA1

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Technical Summary

The 8C-TDOLA1 is a high-density Digital Output (DO) module designed specifically for the Honeywell Experion PKS Series 8 I/O architecture. This module provides 32 channels of discrete control, allowing the C300 controller to manage field devices such as solenoid valves, pilot lights, and motor starters. Built with a focus on cabinet space optimization, the 8C-TDOLA1 features a compact vertical form factor that maintains superior thermal performance and high-speed signal switching for modern process automation requirements.

Hardware Specifications

The technical data provided below outlines the operational parameters and electrical limits for the 8C-TDOLA1 module.

  • Channel Count: 32 Discrete Output Channels

  • Output Type: Current Sourcing (Active high)

  • Operating Voltage: 24 VDC nominal

  • Maximum Current Per Channel: 0.5 A

  • Total Module Current Limit: 16 A (dependent on TBP rating)

  • Response Time: < 5 ms (On/Off)

  • Galvanic Isolation: 2500 VDC (Between field circuitry and logic)

  • Heat Dissipation: 6.5 W (Typical at full load)

  • Short Circuit Protection: Electronic current limiting per channel

  • Diagnostic Capabilities: Integrated loop feedback and module health monitoring

  • Operating Temperature: -40°C to +70°C (-40°F to +158°F)

  • Storage Temperature: -55°C to +85°C

Operational Reliability and Installation

Utilizing the Series 8 Input/Output Termination Assembly (IOTA), the 8C-TDOLA1 supports non-interrupted control through its robust design. The module includes sophisticated diagnostics that can detect field wiring issues, ensuring that the process remains online even during maintenance windows. Its hardware-based current limiting protects the internal circuitry from field-side faults, significantly reducing the Mean Time To Repair (MTTR) by isolating electrical surges.

Frequently Asked Questions

Does the 8C-TDOLA1 support output redundancy?Yes, the 8C-TDOLA1 can be configured in a redundant pair when used with the appropriate Redundant IOTA, ensuring that the control output remains active if one module hardware failure occurs.

How does the module handle over-current events?Each channel is equipped with independent electronic protection. If a solenoid or field device draws current exceeding the 0.5 A threshold, the module will limit the current and report a diagnostic fault to the Experion system without affecting the operation of the remaining 31 channels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more