Product Overview

The 8C-SHEDA1 (P/N 51307186-175) serves as a critical interface component within the Honeywell Experion PKS (Process Knowledge System) C300 infrastructure. This Series 8 Header Board is engineered to facilitate high-speed, reliable data routing and connectivity between I/O modules and the system backplane. Designed for industrial environments demanding high availability, it minimizes signal interference and ensures consistent communication across the automation network.

Technical Specifications

The following data represents the electrical and physical parameters for the 8C-SHEDA1 (51307186-175).

  • Input Voltage: 24V DC (nominal system power)

  • Power Dissipation: 5W

  • Interface Protocol: Ethernet-based proprietary Series 8 communication

  • Form Factor: Compact Series 8 module footprint

  • Physical Dimensions: 120mm x 60mm x 15mm

  • Net Weight: 0.03kg

  • Operating Temperature: -20°C to +70°C

  • Storage Temperature: -40°C to +85°C

  • Relative Humidity: 5% to 95% non-condensing

  • Coating: Conformal coating options available for harsh environment protection

Hardware Compatibility and Application

The 8C-SHEDA1 (51307186-175) is predominantly utilized in Honeywell C300 Controller configurations. It acts as the physical and electrical bridge, ensuring that the Series 8 I/O blocks maintain integrity during high-density data transmission. Its architecture is optimized for:

  • Distributed Control Systems (DCS) integration

  • High-speed process logic execution

  • Real-time data acquisition in oil, gas, and chemical processing

Frequently Asked Questions

Does the 8C-SHEDA1 support redundant configurations?Yes, when installed within the appropriate Experion PKS chassis, this header board supports the redundancy protocols required for mission-critical industrial applications to prevent single points of failure.

What is the primary function of the 51307186-175 in a Series 8 environment?It provides the necessary termination and connection points for the I/O modules to communicate with the C300 controller via the Ethernet-enabled backplane, ensuring low-latency signal processing.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more