Overview
The Honeywell 900A01-0102 Analog Input Module is designed for precise and flexible signal acquisition in process automation and industrial control systems. Supporting up to eight fully isolated input channels, it accepts multiple signal types including thermocouple, RTD, voltage, current, and resistance. Engineered for the ControlEdge HC900 series, this module delivers reliable data conversion, strong electrical isolation, and advanced diagnostics for mission-critical applications.

Technical Specifications

  • Manufacturer: Honeywell

  • Model Number: 900A01-0102

  • Product Type: Analog Input Module

  • Number of Inputs: 8 isolated channels

  • Supported Input Types:

    • Thermocouple (B, E, J, K, R, S, T, N)

    • RTD (Pt100, Pt500, Pt1000, Cu10)

    • Voltage (0–10 V), millivolt (0–100 mV), current (4–20 mA)

    • Resistance and slidewire inputs

  • Input Impedance:

    • Thermocouple/mV: 10 MΩ

    • Current: 250 Ω

    • Voltage: >1 MΩ

  • Galvanic Isolation:

    • 480 VDC channel-to-channel

    • 1 kVDC field-to-logic isolation

  • Noise Rejection:

    • Series Mode: >60 dB

    • Common Mode: >130 dB at 120 VAC

  • Burnout Detection: Configurable for T/C, mV, V, and RTD inputs

  • Accuracy:

    • Factory calibrated: ±0.1% of range

    • Field calibration: ±0.05% of range

    • Cold junction compensation: ±0.7°C

  • A/D Converter: 15-bit resolution, 500 ms update rate

  • Long-Term Stability: 0.1% per year

  • Power Requirements:

    • 5 VDC at 40 mA

    • 24 VDC at 25 mA

  • Calibration Data: Stored in non-volatile memory; supports redundant factory and field calibration

  • Diagnostics: Continuous monitoring of calibration, configuration, and 24 VDC power supply

Key Features

  • Versatile Signal Handling: Supports multiple input formats for flexible sensor integration.

  • Electrical Isolation: Point-to-point and backplane isolation ensure high data integrity.

  • Precision Conversion: 15-bit A/D conversion provides accurate and stable analog measurement.

  • Advanced Diagnostics: Monitors calibration integrity, field wiring, and input signal status.

  • Failsafe Configuration: User-defined failsafe values per channel improve system reliability.

  • Synchronous Sampling: Maintains synchronized analog-to-digital conversion across channels.

  • Modular Design: Integrates seamlessly with Honeywell HC900 and 900 Series controllers.

Application Scenarios
The 900A01-0102 module is used in temperature, pressure, and flow measurement applications across chemical, energy, and manufacturing industries. It enables accurate analog signal acquisition and real-time monitoring in distributed control systems.

FAQ
Q: What signal types can the 900A01-0102 module read?
A: It supports thermocouples, RTDs, mV, V, mA, resistance, and slidewire inputs.

Q: Is field calibration supported?
A: Yes, each channel supports individual field calibration, stored in non-volatile memory.

Q: Can the module detect sensor burnout?
A: Yes, configurable burnout detection is available for T/C, RTD, and voltage inputs.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more