Skip to content

What are you looking for?


You may also like

Honeywell 51309218-125 | MU-TAMR03 | Low Level Analog Input Multiplexer RTD FTAHoneywell 51309218-125 | MU-TAMR03 | Low Level Analog Input Multiplexer RTD FTAHoneywell 51309218-125 | MU-TAMR03 | Low Level Analog Input Multiplexer RTD FTA
Honeywell 51309218-125 | MU-TAMR03 | Low Level Analog Input Multiplexer RTD FTA
Honeywell 51309218-125 | MU-TAMR03 | Low Level Analog Input Multiplexer RTD FTA
Honeywell 51309218-125 | MU-TAMR03 | Low Level Analog Input Multiplexer RTD FTA

Honeywell 51309218-125 | MU-TAMR03 | Low Level Analog Input Multiplexer RTD FTA


Only 10 left - Selling fast

PRODUCT SKU : MU-TAMR03 501309218-125

PRODUCT TYPE : Analog Input Multiplexer

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The MU-TAMR03 (51309218-125) is a specialized Low Level Analog Input Multiplexer (LLMux) Field Termination Assembly designed specifically for Resistance Temperature Detector (RTD) inputs. This module serves as the critical physical interface between field-mounted temperature sensors and the Honeywell TDC 3000 or Experion PKS control systems.

Engineered for high-density temperature monitoring, the MU-TAMR03 (51309218-125) supports 16 independent input channels. This specific hardware revision features rugged compression-style terminals, ensuring secure and vibration-resistant physical wire terminations for sensitive low-level signals. Note that this version is non-conformally coated and is intended for use in environments where CE compliance is not a regulatory requirement.

Detailed Engineering Specifications

  • Input Configuration: 16-Channel RTD Multiplexer

  • Input Level: Low Level Analog (optimized for ohms/temperature conversion)

  • Termination Type: Compression terminals (screw-down)

  • Interface Architecture: Single IOP (Input Output Processor) interface

  • System Redundancy: Non-redundant configuration only

  • Environmental Protection: Non-conformally coated (standard board)

  • Regulatory Status: Non-CE compliant version

  • Module Weight: Approximately 5.0 kg (11.0 lbs) shipping mass

  • Mounting Integration: Designed for standard Honeywell FTA mounting channels

Application Scenarios

The MU-TAMR03 (51309218-125) is typically utilized in large-scale industrial plants where high-density RTD monitoring is required, such as:

  • Bearing temperature monitoring for large rotating equipment.

  • Multi-point distillation column temperature profiling.

  • Heat exchanger efficiency monitoring.

  • General balance-of-plant temperature data acquisition.

Frequently Asked Questions

Is the MU-TAMR03 compatible with redundant IOPs?

No. The MU-TAMR03 (51309218-125) is a single IOP interface assembly and does not support redundant hardware architectures.

Does this module include protection for corrosive environments?

This specific part number (51309218-125) is not conformally coated. For applications in "G3" or corrosive environments, a coated version should be specified.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more