Product Overview

The Honeywell 51305072-200 acts as a high-performance CLCN-A Local Control Network (LCN) interface card within the Honeywell TDC 3000 distributed control architecture. This module establishes a deterministic, high-speed communication path between individual system nodes and the primary LCN backbone over ControlNet protocols. We deliver this hardware in 100% brand new, original factory condition to ensure seamless network integration, eliminate transmission drops, and preserve system integrity.

Technical Specifications

Parameter Specification
Card Type CLCN-A LCN Interface Card
System Compatibility Honeywell TDC 3000
Communication Protocol ControlNet
Data Transmission Speed 5 Mbps
Memory Capacity 50 MB
Cable Interface & Connector LCN "A" coaxial cable with BNC tees
Power Supply Requirements 24V DC ±10%
Power Consumption 15W
Mounting Configuration Dual-node chassis
Ingress Protection Rating IP20
Operating Temperature -20°C to +55°C
Storage Temperature -40°C to +85°C
Physical Dimensions 180 x 70 x 40 mm
Net Weight 180g

Engineering Advantages

  • Prevents Total Network Disruption During Maintenance: The integrated BNC tee connector design allows instrumentation engineers to disconnect individual nodes for servicing without breaking the coaxial loop or dropping communication to adjacent live nodes.

  • Maintains Throughput in High-Traffic Environments: The onboard 50MB memory buffer processes deterministic ControlNet traffic at a sustained 5 Mbps, preventing packet loss during heavy plant upset conditions.

  • Lowers Panel Thermal Load: The highly optimized circuitry draws only 15W of 24V DC power, minimizing heat dissipation inside enclosed dual-node chassis and extending the lifespan of neighboring components.

  • Fits Compact System Rack Enclosures: The streamlined 180 x 70 x 40 mm footprint easily slots into standard dual-node chassis alignments, resolving the challenge of upgrading legacy systems within constrained physical layouts.

FAQs

  • Can I disconnect this card from the network while the rest of the DCS system operates?

    Yes. The 51305072-200 utilizes specialized BNC tees. This feature allows you to isolate and remove the specific node for replacement or diagnostics without breaking the LCN "A" coaxial ring continuity.

  • Does this product arrive in surplus or re-certified condition?

    No. We sell this product strictly as a 100% brand new, authentic factory piece. It includes all original packaging and seals from the manufacturer.

  • What are the grounding requirements during the installation of this interface card?

    You must slide the card firmly into the dual-node chassis slots until the integrated grounding clips fully engage the metal rack frame. Always wear an ESD wrist strap during this procedure to protect the 50MB internal memory and processing chips from static damage.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more