Product Description

The Honeywell 10101/1/1 Digital Input Module is a fail-safe unit designed for Honeywell distributed control systems. It provides 16 optically isolated digital inputs, ensuring secure signal acquisition and electrical isolation. With Form C contact outputs and robust fail-safe operation, the module is engineered for reliable performance in demanding industrial environments. Its DIN rail mounting capability allows straightforward installation in compact control panels.

Key Features

  • Model Number: 10101/1/1

  • Channels: 16 optically isolated digital inputs

  • Input Voltage: 24 VDC nominal, 20–30 VDC range

  • Input Current: 10 mA maximum per channel

  • Input Impedance: 2 kΩ

  • Output Type: Form C contact outputs

  • Output Voltage: Matches input voltage

  • Output Current: 250 mA maximum per channel

  • Fail-safe Operation: Maintains safe state during power loss or fault conditions

  • Mounting: DIN rail compatible for easy installation

  • Operating Temperature: –40 °C to +70 °C (–40 °F to +158 °F)

  • Storage Temperature: –40 °C to +85 °C (–40 °F to +185 °F)

  • Humidity Range: 0–95% RH, non-condensing

  • Vibration Resistance: 5 g, 20–500 Hz

  • Shock Resistance: 15 g for 11 ms

Application Scenarios

  • Safety-Critical Systems: Reliable input monitoring for distributed control systems

  • Industrial Automation: Integration of sensors, switches, and alarms into Honeywell DCS platforms

  • Compact Installations: DIN rail mounting for space-efficient control panels

  • Harsh Environments: Wide operating temperature and vibration resistance for rugged conditions

FAQ

Q: How many input channels does the 10101/1/1 provide?  A: It supports 16 optically isolated digital input channels.

Q: What type of outputs are available?  A: The module provides Form C contact outputs rated up to 250 mA per channel.

Q: What is the operating voltage range?  A: The input voltage range is 20–30 VDC, with a nominal rating of 24 VDC.

Q: How does it compare to the Honeywell 10101/2/3 module?  A: The 10101/1/1 is optimized for 24 VDC inputs with Form C outputs, while the 10101/2/3 supports a wider input voltage range (24–48 VDC) and higher output current capacity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more