Skip to content

What are you looking for?


You may also like

900RTA-L001 Analog Input Remote Terminal Assembly | Honeywell900RTA-L001 Analog Input Remote Terminal Assembly | Honeywell900RTA-L001 Analog Input Remote Terminal Assembly | Honeywell
900RTA-L001 Analog Input Remote Terminal Assembly | Honeywell
900RTA-L001 Analog Input Remote Terminal Assembly | Honeywell
900RTA-L001 Analog Input Remote Terminal Assembly | Honeywell

900RTA-L001 Analog Input Remote Terminal Assembly | Honeywell


Only 10 left - Selling fast

PRODUCT SKU : 900RTA-L001

PRODUCT TYPE : Remote Terminal Assemblies

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 900RTA-L001, also cataloged as the 900RTA-L001 Remote Terminal Adapter (RTA), operates as a dedicated hardware component for field sensor signal wiring termination and signal routing within Honeywell HC900 Control System platforms.

Hardware Specifications

Parameter Specification
Model 900RTA-L001
Brand Honeywell
Origin USA
Weight 0.4 kg
Dimensions 120 x 90 x 60 mm
Operating Temp -20 to 70 deg C
Power Consumption Up to 10 W
System Platform Honeywell HC900 Control System
Input Capacity 16 analog input channels
Input Signal Ranges 0 to 10 VDC, 4-20 mA
Resolution / Accuracy 12 bits / +/-0.1% of full scale
Power Supply 24 VDC
Hazardous Approvals Class I, Div 2, Groups A,B,C,D T6; Class I, Zone 2, Group IIC
Mounting Format 35 mm wide DIN-rail or panel mount

Channel-to-Channel Isolation and Analog Input Processing

The 900RTA-L001 remote terminal assembly provides 16 high-density wiring termination points for field analog transmitters. Built to process 0-10 VDC and 4-20 mA HART loop protocol signals, the unit incorporates active signal conditioning logic to enforce high channel-to-channel isolation parameters across adjacent process loops. High-grade dielectric isolation barriers protect central HC900 logic controllers from field common-mode noise, earth potential ground loops, and transient voltage spikes occurring along field wiring runs.

Frequently Asked Questions

Q: How are 4-20 mA field current loops converted to voltage signals for processing on the terminal board?

A: The panel uses precision internal shunt resistors across input terminals to convert 4-20 mA current loops into equivalent proportional DC voltage inputs for the analog input module.

Q: Can the 900RTA-L001 terminal assembly be mounted directly inside Class I, Division 2 locations?

A: Yes, the unit carries official Class I, Division 2 (Groups A, B, C, D T6) and Class I, Zone 2 (Group IIC) hazardous location certifications.

Q: Is hot-swapping supported for the interconnect cable linking the RTA panel to the main I/O module?

A: Cable removal must be executed with field power disabled or following proper hazardous location live-work permits to avoid process disruption or electrical arcing.

Field Installation Guidelines

  1. Snap the 900RTA-L001 assembly securely onto a standard 35 mm DIN-rail or fasten it directly to the enclosure mounting plate using screws.
  2. Route 4-20 mA and 0-10 VDC field instrument wiring into screw terminals, observing polarity markings on the board print.
  3. Torque all terminal connections to specified ratings to ensure reliable electrical contact under high-vibration conditions.
  4. Segregate field analog signal cables from high-voltage AC lines and motor drive cables inside cabinet wire channels.
  5. Connect cable shield drain wires to the dedicated cabinet instrumentation earth bus bar, ensuring proper single-point grounding.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more