8C-PDIS01 | Honeywell | Series 8 Digital Input SOE Module8C-PDIS01 | Honeywell | Series 8 Digital Input SOE Module8C-PDIS01 | Honeywell | Series 8 Digital Input SOE Module
8C-PDIS01 | Honeywell | Series 8 Digital Input SOE Module
8C-PDIS01 | Honeywell | Series 8 Digital Input SOE Module
8C-PDIS01 | Honeywell | Series 8 Digital Input SOE Module

8C-PDIS01 | Honeywell | Series 8 Digital Input SOE Module


Only 10 left - Selling fast

PRODUCT SKU : 8C-PDIS01

PRODUCT TYPE : Sequence of Events Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Module Overview

The 8C-PDIS01 is a high-performance Sequence of Events (SOE) Digital Input module integrated within the Honeywell Experion PKS Series 8 platform. Engineered for critical monitoring where timing precision is non-negotiable, this module captures state changes with millisecond accuracy. Its architectural design prioritizes signal integrity in high-interference environments, making it a standard choice for turbine control, emergency shutdown systems, and complex process interlocking.

Technical Parameters

The following specifications define the electrical and environmental limits of the 8C-PDIS01 hardware:

  • Channel Density: 16 isolated input channels

  • Nominal Input Voltage: 24 VDC

  • Input Current Loading: 2 mA per channel at rated voltage

  • SOE Time Stamp Precision: 1 ms resolution for event logging

  • Galvanic Isolation: 2500 Vrms (tested channel-to-logic)

  • Field Side Voltage Range: 18 VDC to 30 VDC

  • ON State Threshold: > 13 VDC

  • OFF State Threshold: < 5 VDC

  • Operating Ambient Temperature: -40°C to +70°C (-40°F to +158°F)

  • Storage Temperature Range: -55°C to +85°C

  • Humidity Limits: 5% to 95% RH (non-condensing)

  • Conformal Coating: Standard for Series 8 ruggedization

Application and Deployment

The 8C-PDIS01 module is typically deployed in scenarios requiring post-trip analysis or precise causal sequence tracking. By utilizing the 1ms time-stamping capability, engineers can reconstruct the exact order of field contact closures during a system upset. It mounts directly onto the Series 8 Input/Output Termination Assembly (IOTA), allowing for vertical airflow and efficient heat dissipation within the control cabinet.

Frequently Asked Questions

Does the 8C-PDIS01 require external power for the field inputs?Yes, the 24 VDC loop power must be provided to the field contacts, as the module acts as a sinking input device to detect the presence of voltage.

What is the difference between this SOE module and a standard Digital Input module?While a standard DI module scans inputs based on the controller's execution cycle, the 8C-PDIS01 features local processors that timestamp transitions immediately at the hardware level, bypassing controller scan-time jitter.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more