Skip to content

What are you looking for?


You may also like

Honeywell 51402614-100 Ethernet Board ModuleHoneywell 51402614-100 Ethernet Board ModuleHoneywell 51402614-100 Ethernet Board Module
Honeywell 51402614-100 Ethernet Board Module
Honeywell 51402614-100 Ethernet Board Module
Honeywell 51402614-100 Ethernet Board Module

Honeywell 51402614-100 Ethernet Board Module


Only 10 left - Selling fast

PRODUCT SKU : 51402614-100

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for TCP/IP-based communication in Honeywell TPS/LCN operator and controller stations, the Honeywell 51402614-100 (51402614-100 Ethernet Board Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 51402614-100
Brand Honeywell
Origin USA
Weight Approx. 0.2 kg
Dimensions 120 mm x 80 mm x 30 mm
Operating Temp 0 to 60 deg C
Power Consumption 5 VDC +/- 5% (Max 3 W)
Module Type Ethernet Board Module
Communication Protocols TCP/IP, ARP
Data Rate Up to 10 Mbps
System Compatibility Honeywell TPS/LCN operator and controller stations
Installation Board-level installation within station hardware

Channel Isolation & Network Protocol Execution

Designed for real-time process control data routing, the module executes deterministic Ethernet frame transfers across station backplane architectures. Integrated channel-to-channel isolation safeguards sensitive internal logic circuitry from transient voltage spikes and differential ground potential offsets. The onboard physical layer interface manages ARP packet verification and TCP/IP stack execution, maintaining continuous connection integrity between operator stations and low-level process controllers without imposing CPU processing overhead on the host node.

Frequently Asked Questions

Q: What input supply voltage does the 51402614-100 board require from the host backplane?

A: The board operates on a regulated 5 VDC +/- 5% power rail, consuming a maximum power load of 3 W during active network data transmission.

Q: Which network communication protocols are implemented on this hardware module?

A: The module directly supports TCP/IP and ARP protocols over Ethernet interfaces operating at data rates up to 10 Mbps.

Q: How is physical frame grounding established during board installation?

A: Grounding is established via the board mounting chassis points and frame retention screws, which bond the ground plane directly to the host enclosure chassis upon installation.

Field Installation Guidelines

  1. Disconnect all electrical power sources from the target Honeywell TPS/LCN station chassis before accessing internal slots.
  2. Wear a grounded wrist strap attached to frame ground to prevent electrostatic discharge damage to board components.
  3. Align the 51402614-100 circuit board edges with the card guide rails inside the designated station slot.
  4. Press the module smoothly into place until the multi-pin edge connectors seat completely into the host backplane.
  5. Tighten all mechanical mounting screws to ensure proper electrical contact for frame grounding and mechanical stability.
  6. Verify external coaxial or twisted-pair network cable connections before re-energizing the station power supply.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more