The Honeywell TL-Q5MC1, also cataloged as the TL-Q5MC1 Inductive Proximity Sensors, operates as a dedicated hardware component for non-contact metallic target detection within automated industrial sensing loops.

Hardware Specifications

Parameter Specification
Model TL-Q5MC1
Brand Honeywell
Origin USA / Global Manufacturing
Operating Temp -25 to +70 deg C
Power Consumption Current consumption <= 10 mA at 24 VDC
Supply Voltage Range 10-30 VDC (Rated: 12-24 VDC, ripple < 10%)
Output Type NPN open collector
Output Configuration Normally Open (NO)
Max Switching Current 50 mA
Max Load Voltage 30 VDC
Residual Voltage <= 1 V at 50 mA (2 m cable)
Response Frequency 500 Hz
Response Time <= 2 ms
Protection Circuits Reverse polarity protection, surge suppression

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

When integrated alongside analog field instrumentation, the TL-Q5MC1 digital switching signals pass to DCS discrete input channels without inducing switching noise into adjacent 4-20 mA HART loop protocol lines. Internal surge suppression network components absorb transient voltage spikes during high-frequency actuation up to 500 Hz.

Maintaining proper channel-to-channel isolation on the receiving I/O termination block ensures that NPN open collector switching currents up to 50 mA do not alter analog loop current references or disrupt low-level digital telecommunication layers across neighboring terminal blocks.

Frequently Asked Questions

Q: What is the maximum switching frequency supported by the TL-Q5MC1 proximity sensor?

A: The sensor operates at a maximum response frequency of 500 Hz with a maximum response time of 2 ms.

Q: Does the TL-Q5MC1 include internal protection against reversed supply wiring?

A: Yes, the sensor includes built-in reverse polarity protection and surge suppression circuitry to prevent internal component damage.

Q: What electrical load limitations apply to the NPN output stage?

A: The NPN open collector output handles a maximum switching current of 50 mA with a maximum load voltage of 30 VDC.

Field Installation Guidelines

  • Verify input voltage supply limits are within 10-30 VDC with ripple below 10% before applying system power.
  • Ensure target metal mass meets standard sensing face alignment requirements to guarantee full 500 Hz switching capability.
  • Connect sensor cable shielding to the designated earth ground terminal in the junction box to prevent EMI coupling.
  • Maintain physical isolation between sensor signal cabling and high-power AC motor or drive wiring in cabinet channels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more