Skip to content

What are you looking for?


You may also like

MU-TAOX12 | Honeywell 8-Channel Analog Output Field Termination Assembly (FTA)MU-TAOX12 | Honeywell 8-Channel Analog Output Field Termination Assembly (FTA)MU-TAOX12 | Honeywell 8-Channel Analog Output Field Termination Assembly (FTA)
MU-TAOX12 | Honeywell 8-Channel Analog Output Field Termination Assembly (FTA)
MU-TAOX12 | Honeywell 8-Channel Analog Output Field Termination Assembly (FTA)
MU-TAOX12 | Honeywell 8-Channel Analog Output Field Termination Assembly (FTA)

MU-TAOX12 | Honeywell 8-Channel Analog Output Field Termination Assembly (FTA)


Only 10 left - Selling fast

PRODUCT SKU : MU-TAOX12 51304335-100

PRODUCT TYPE : Analog Output Terminal Assembly

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Technical Product Overview

The MU-TAOX12 serves as a specialized 8-point Analog Output Field Termination Assembly (FTA) within the Honeywell TDC 3000 and Experion PKS ecosystems. Engineered for high-precision current loop control, this module converts digital commands into stable 4-20mA signals to drive actuators, valves, and positioners.

A critical engineering advantage of the MU-TAOX12 is its elevated field terminal voltage overhead. Compared to standard assemblies like the MU-GAIH13 or MU-GAIH83, this model provides increased drive capability, effectively overcoming higher impedance in extended field wiring runs without compromising signal integrity.

Detailed Engineering Specifications

  • Signal Architecture: 8-Channel isolated current output (typically 4-20mA)

  • Digital Resolution: 12-bit D/A conversion for granular control

  • Calibration Accuracy: ±0.1% of full-scale range at reference conditions

  • Input Power Requirement: Nominal 24 VDC

  • Environmental Range: Rated for operation from -40°C to +70°C (-40°F to 158°F)

  • Drive Capacity: Enhanced voltage rails to support long-distance cable loops

  • Reliability Features: Supports redundant processor configurations for mission-critical loops

  • Form Factor: Approximately 14.5 x 10.5 x 3.5 inches

  • Physical Mass: 2.2 lbs (1.0 kg)

  • Installation Standards: Designed for Rittal cabinet mounting using Honeywell-certified hardware

Installation and Hardware Compliance

To maintain the thermal and electromagnetic certification of the MU-TAOX12, the assembly must be housed within a standard Rittal enclosure. Integration requires the use of official Honeywell/Rittal mounting brackets and standoffs. Adhering to these structural requirements ensures the ±0.1% accuracy is maintained even in high-vibration or variable-temperature industrial environments.

Functional Comparison: MU-TAOX12 vs. MU-GAIH13

While both units handle analog signals, the MU-TAOX12 is specifically optimized for output drive. The primary differentiator is the "Field Terminal Voltage." The MU-TAOX12 allows for significantly longer wiring distances between the DCS cabinet and the field device, as it can source higher voltage to push the 20mA signal through increased loop resistance.

Frequently Asked Questions

Does the MU-TAOX12 support redundancy?

Yes. The MU-TAOX12 can be configured in a redundant architecture to ensure that a processor failure does not result in the loss of control over the analog output loops.

Can this unit be used with non-Honeywell mounting hardware?

Honeywell documentation strictly specifies standard Rittal mounting hardware to ensure proper grounding and physical support. Using third-party hardware may void the mechanical warranty.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering PLC Programming: Best Practices for Robust Industrial Automation

Mastering PLC Programming: Best Practices for Robust Industrial Automation

Writing clean PLC code requires discipline, especially regarding memory management. Avoid overusing SET and RESET instructions, as they often complicate debugging. If multiple rungs control the same bit, troubleshooting becomes a nightmare. Instead, focus on energizing a bit in only one location. If your logic requires complex conditions, use branches within a single rung. This approach keeps your code readable, maintainable, and significantly easier to audit during downtime.

Read more
PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

In the realm of industrial automation, distinguishing between a Programmable Logic Controller (PLC) and a Human-Machine Interface (HMI) is fundamental. While both devices work in tandem, they serve distinct purposes. The PLC acts as the "brain" of the operation, executing logic, whereas the HMI serves as the "eyes," allowing operators to monitor and interact with the system. Understanding this synergy is essential for any professional designing robust factory automation solutions.

Read more
Selecting the Right Industrial Automation Solution for Modern Manufacturing

Selecting the Right Industrial Automation Solution for Modern Manufacturing

Choosing an effective industrial automation system starts with a thorough process audit. You must identify tasks that are repetitive, labor-intensive, or prone to human error. Not every process requires high-level automation; therefore, prioritize operations that directly impact throughput and quality. By scoping your needs accurately, you avoid over-investing in unnecessary technology. A balanced approach ensures that your capital expenditure aligns with measurable gains in operational efficiency.

Read more