Skip to content

What are you looking for?


You may also like

MU-TAIH22 80366195-100 Enhanced Power High-Level Analog Input FTA | HoneywellMU-TAIH22 80366195-100 Enhanced Power High-Level Analog Input FTA | HoneywellMU-TAIH22 80366195-100 Enhanced Power High-Level Analog Input FTA | Honeywell
MU-TAIH22 80366195-100 Enhanced Power High-Level Analog Input FTA | Honeywell
MU-TAIH22 80366195-100 Enhanced Power High-Level Analog Input FTA | Honeywell
MU-TAIH22 80366195-100 Enhanced Power High-Level Analog Input FTA | Honeywell

MU-TAIH22 80366195-100 Enhanced Power High-Level Analog Input FTA | Honeywell


Only 10 left - Selling fast

PRODUCT SKU : MU-TAIH22 80366195-100

PRODUCT TYPE : Analog Input FTA

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell MU-TAIH22 80366195-100 serves as an Enhanced Power High-Level Analog Input (HLAI) Field Termination Assembly (FTA). This 100% Brand New and original module interfaces field sensors with the control system, providing 16 high-precision analog input channels. It specifically supports STI (Safety Test Interval) functionality, ensuring signal integrity in demanding DCS (Distributed Control System) environments.

Technical Specifications

Feature Specification
Manufacturer Honeywell Inc.
Model Number MU-TAIH22 / 80366195-100
Input Channels 16 Analog Inputs
Input Range ±10V
Accuracy 0.1% of Full Scale
Resolution 0.01% of Full Scale
Response Time < 100 ms
Signal Noise < 20 μV RMS
Operating Temperature -40°C to +70°C
Power Requirement 24 VDC, 100 mA
Dimensions 120 x 80 x 30 mm
Weight 0.3 kg

Engineering Advantages

  • Superior Signal Clarity: This module maintains crosstalk at less than 0.1% and limits noise to under 20 μV RMS. This precision ensures that low-level signal fluctuations do not trigger false process alarms or control oscillations.

  • Extreme Thermal Endurance: The hardware operates reliably between -40°C and +70°C. This wide range allows installation in remote instrument enclosures without the need for supplementary HVAC systems, reducing overall infrastructure costs.

  • Enhanced Power Density: The "Enhanced Power" designation means the FTA manages higher current loads for field-side loops more effectively than standard versions. This prevents voltage drops during peak demand across the 16-channel array.

  • Compact Footprint: Measuring only 120x80x30mm, the MU-TAIH22 optimizes rail space. This compact profile solves the common industrial pain point of overcrowded marshalling cabinets during system expansions.

  • Robust Isolation: The design protects the primary controller from field-side electrical surges, ensuring that a fault on a single analog loop does not compromise the entire I/O rack.

FAQs

  • How does this "Enhanced Power" version differ from standard HLAI modules?

    The MU-TAIH22 80366195-100 features upgraded power handling components. It maintains tighter voltage regulation and supports more robust field-side signal loops compared to non-enhanced legacy models.

  • Is this module a direct replacement for older TAIH units?

    Yes, provided the system configuration supports the 80366195-100 part number. It typically replaces older revisions while offering improved thermal stability and lower noise floors.

  • What are the wiring requirements for the 16 channels?

    The module utilizes standard terminal connections. To maintain the 0.1% accuracy specification, engineers should use shielded twisted-pair cabling and follow the specific grounding protocols outlined in the Honeywell Experion PKS installation guide.

  • Do you provide original factory warranty with this unit?

    We supply this product as 100% Brand New in original factory packaging. It carries the full manufacturer’s assurance of quality and is sourced directly from certified industrial inventory.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more