PRODUCT SKU : MU/MC-TAOX12 51304335-125

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The MU/MC-TAOX12 51304335-125 serves as a critical interface component within the Honeywell Experion PKS (Process Knowledge System) architecture. This Analog Output (AO) termination assembly is engineered to facilitate precise signal transmission from the controller to field-mounted final control elements, such as valves and actuators.

Designed for high-reliability industrial environments, the module supports 12-channel output configurations. It ensures seamless integration with I/O processors, providing robust electrical termination and signal conditioning to maintain loop integrity in complex automation loops.

Technical Specifications

  • Model Number: MU/MC-TAOX12

  • Part Number: 51304335-125

  • Module Type: Analog Output Termination Assembly (TA)

  • Channel Density: 12 Channels

  • System Compatibility: Honeywell TDC 3000 / Experion PKS Systems

  • Signal Range: 4-20 mA standard industrial current loops

  • Mounting Configuration: Standard I/O Rack / Cabinet Mounting

  • Redundancy Support: Compatible with redundant I/O processor configurations

  • Operating Temperature: 0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit)

  • Humidity Limits: 5% to 95% RH (non-condensing)

Application Context

This module is primarily utilized in sectors requiring stringent process control, including oil and gas refining, chemical processing, and power generation. It acts as the physical connection point for field wiring, allowing for easy maintenance and diagnostic testing of 4-20 mA control loops without disrupting the primary system backbone.

Frequently Asked Questions

  • Is the MU/MC-TAOX12 compatible with older TDC 3000 systems?

    Yes, this termination assembly is designed to support legacy TDC 3000 integrations while remaining a standard component for modern Experion PKS upgrades.

  • What is the primary difference between the MC and MU prefixes?

    The prefix often denotes the coating or mounting orientation (Uncoated vs. Coated), with MU/MC-TAOX12 typically referring to the non-conformal coated version used in standard control room environments.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more