Skip to content

What are you looking for?


You may also like

Honeywell MC-TSIM12 51303932-476 Serial Device Interface Termination ModuleHoneywell MC-TSIM12 51303932-476 Serial Device Interface Termination ModuleHoneywell MC-TSIM12 51303932-476 Serial Device Interface Termination Module
Honeywell MC-TSIM12 51303932-476 Serial Device Interface Termination Module
Honeywell MC-TSIM12 51303932-476 Serial Device Interface Termination Module
Honeywell MC-TSIM12 51303932-476 Serial Device Interface Termination Module

Honeywell MC-TSIM12 51303932-476 Serial Device Interface Termination Module


Only 10 left - Selling fast

PRODUCT SKU : MC-TSIM12 51303932-476

PRODUCT TYPE : Serial Interface Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell MC-TSIM12 (Part Number: 51303932-476) functions as a high-performance Serial Device Interface Termination Module within the Honeywell Distributed Control System (DCS). It establishes a secure communication bridge between the controller and various serial field devices. This module prioritizes system hardware integrity by neutralizing electrical anomalies before they reach the logic processor. We supply this unit in 100% Brand New, original factory condition, ensuring your communication network operates with maximum uptime and zero signal interference.

Technical Specifications

Feature Specification Detail
Model Number MC-TSIM12
Part Number 51303932-476
Primary Function Serial Network Termination & Surge Suppression
Input Voltage Range 10 to 30 VDC
Isolation Voltage 1500 VDC
Output Current 10 mA
Response Time 1 ms
Protection Circuitry Overvoltage and Electrostatic Discharge (ESD)

Engineering Advantages

  • High-Voltage Galvanic Isolation: The MC-TSIM12 provides 1500 VDC isolation, which physically separates field-side serial loops from the sensitive DCS backplane. This barrier prevents ground loops and catastrophic damage during major electrical faults.

  • Millisecond Surge Suppression: The internal circuitry reacts in less than 1 ms to overvoltage transients. This rapid response clamps voltage spikes caused by inductive load switching or atmospheric interference, shielding your serial device network from data corruption.

  • Integrated ESD Shielding: Industrial environments generate significant static electricity. The MC-TSIM12 incorporates specialized ESD protection components that dissipate static charges, preventing the "frozen" communication ports often seen in unprotected serial interfaces.

  • Stable Serial Termination: The module provides precise impedance matching for serial networks. Proper termination eliminates signal reflections (ghosting), ensuring that high-speed data packets remain intact across long cable runs in complex plant architectures.

  • Wide Voltage Tolerance: Operating across a 10 to 30 VDC range, this module compensates for the voltage drops common in large-scale industrial power distribution networks, maintaining consistent performance without requiring additional power conditioning.

FAQs

  • How does the MC-TSIM12 handle signal noise in high-interference areas?

    The module utilizes 1500 VDC isolation and dedicated surge suppression to filter out common-mode noise. By terminating the serial link correctly at the hardware level, it maintains a high signal-to-noise ratio even near high-voltage motors or variable frequency drives.

  • Is this module a direct replacement for older serial termination cards?

    The MC-TSIM12 (51303932-476) follows standard Honeywell serial interface specifications. However, always verify your existing I/O processor firmware and serial protocol (RS-232/485) compatibility before installing new hardware into a legacy rack.

  • Does the unit come with the original factory seal?

    Yes. We guarantee that every MC-TSIM12 is 100% Brand New. It ships in original Honeywell packaging with factory serial numbers, ensuring you receive genuine hardware that has never been installed or refurbished.

  • What is the significance of the 1 ms response time?

    In industrial automation, voltage spikes occur in microseconds. The 1 ms response time ensures that the protection circuitry activates fast enough to bypass the surge, preventing the energy from reaching the internal components of your connected serial devices.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more