Skip to content

What are you looking for?


You may also like

Honeywell MC-TAOY25 51305865-275 Experion PKS HART-Enabled Analog Output FTAHoneywell MC-TAOY25 51305865-275 Experion PKS HART-Enabled Analog Output FTAHoneywell MC-TAOY25 51305865-275 Experion PKS HART-Enabled Analog Output FTA
Honeywell MC-TAOY25 51305865-275 Experion PKS HART-Enabled Analog Output FTA
Honeywell MC-TAOY25 51305865-275 Experion PKS HART-Enabled Analog Output FTA
Honeywell MC-TAOY25 51305865-275 Experion PKS HART-Enabled Analog Output FTA

Honeywell MC-TAOY25 51305865-275 Experion PKS HART-Enabled Analog Output FTA


Only 10 left - Selling fast

PRODUCT SKU : MC-TAOY25 51305865-275

PRODUCT TYPE : Analog Output FTA

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell MC-TAOY25 (51305865-275) functions as a high-performance, 16-channel Analog Output Field Termination Assembly (FTA) specifically designed for the Honeywell Experion PKS and legacy TDC 3000 control environments. This 100% Brand New and original module manages critical control signals for final control elements like control valves and variable speed drives. By integrating native HART protocol support, it enables bi-directional communication, allowing the Distributed Control System (DCS) to perform remote diagnostics and instrument configuration directly through the analog loop.

Technical Specifications

Feature Specification Details
Manufacturer Honeywell
Model Number MC-TAOY25
Part Number 51305865-275
Output Channels 16 Analog Outputs
Protocol HART-enabled (Highway Addressable Remote Transducer)
Mounting Field Termination Assembly (FTA) compatible
Country of Origin U.S.A.
Dimensions 115 x 75 x 35 mm (approx.)
Weight 0.14 - 0.4 kg
Warranty 12 Months

Engineering Advantages

  • Native HART Integration: The MC-TAOY25 supports HART digital communication superimposed on the 4-20mA signal. This allows maintenance teams to access valve positioner diagnostics, device status, and configuration parameters remotely from the control room, significantly reducing the need for field-side instrument technician deployment.

  • Simplified Marshalling Architecture: The module consolidates 16 output channels into a compact FTA footprint. This high-density design optimizes vertical space within marshalling cabinets, solving the common industrial challenge of limited enclosure real estate during system expansions.

  • USA-Manufactured Reliability: Built in the United States, this FTA adheres to stringent quality control standards. The ruggedized PCB substrate and high-quality termination points ensure long-term electrical contact integrity, even in the presence of continuous industrial vibration.

  • Streamlined Troubleshooting: The FTA architecture provides easy access for multi-meter probing. Engineers can verify loop current and HART signal strength directly at the terminal block, which accelerates the commissioning process and minimizes downtime during emergency maintenance.

  • Seamless Legacy Migration: The 51305865-275 maintains mechanical and electrical compatibility with existing Honeywell I/O chassis. This allows for a straightforward upgrade path for facilities looking to add HART capabilities to older non-HART analog output loops without re-wiring the entire cabinet.

FAQs

  • What is the advantage of the MC-TAOY25 over non-HART analog output modules?

    The MC-TAOY25 allows the system to "speak" to smart field instruments. Beyond simply sending a 4-20mA command, the HART capability enables the DCS to read secondary variables, such as actual valve travel or internal temperature, which provides a deeper level of asset health monitoring.

  • Is this module a direct replacement for previous Honeywell AO FTA models?

    The 51305865-275 often serves as an upgrade for legacy analog output FTAs. While it maintains physical compatibility, ensure your I/O processors (such as the High-Performance Process Manager or Series C I/O) support HART pass-through to fully utilize the digital diagnostic features.

  • Does this unit come with a warranty and certification of origin?

    Yes. We supply only 100% Brand New original Honeywell units manufactured in the USA. Every purchase includes a 12-month warranty. Each unit arrives in factory-original packaging with verifiable serial numbers for full asset traceability.

  • How do I handle installation to ensure maximum noise immunity for the HART signal?

    We recommend utilizing shielded twisted-pair cabling for all 16 channels. Ensure the shield terminates at the marshalling cabinet’s ground bus to prevent electromagnetic interference (EMI) from corrupting the high-frequency HART digital carrier.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering PLC Programming: Best Practices for Robust Industrial Automation

Mastering PLC Programming: Best Practices for Robust Industrial Automation

Writing clean PLC code requires discipline, especially regarding memory management. Avoid overusing SET and RESET instructions, as they often complicate debugging. If multiple rungs control the same bit, troubleshooting becomes a nightmare. Instead, focus on energizing a bit in only one location. If your logic requires complex conditions, use branches within a single rung. This approach keeps your code readable, maintainable, and significantly easier to audit during downtime.

Read more
PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

In the realm of industrial automation, distinguishing between a Programmable Logic Controller (PLC) and a Human-Machine Interface (HMI) is fundamental. While both devices work in tandem, they serve distinct purposes. The PLC acts as the "brain" of the operation, executing logic, whereas the HMI serves as the "eyes," allowing operators to monitor and interact with the system. Understanding this synergy is essential for any professional designing robust factory automation solutions.

Read more
Selecting the Right Industrial Automation Solution for Modern Manufacturing

Selecting the Right Industrial Automation Solution for Modern Manufacturing

Choosing an effective industrial automation system starts with a thorough process audit. You must identify tasks that are repetitive, labor-intensive, or prone to human error. Not every process requires high-level automation; therefore, prioritize operations that directly impact throughput and quality. By scoping your needs accurately, you avoid over-investing in unnecessary technology. A balanced approach ensures that your capital expenditure aligns with measurable gains in operational efficiency.

Read more