Skip to content

What are you looking for?


You may also like

Honeywell Experion PKS Serial Interface I/O Processor | MC-PSIM11 51304362-350Honeywell Experion PKS Serial Interface I/O Processor | MC-PSIM11 51304362-350Honeywell Experion PKS Serial Interface I/O Processor | MC-PSIM11 51304362-350
Honeywell Experion PKS Serial Interface I/O Processor | MC-PSIM11 51304362-350
Honeywell Experion PKS Serial Interface I/O Processor | MC-PSIM11 51304362-350
Honeywell Experion PKS Serial Interface I/O Processor | MC-PSIM11 51304362-350

Honeywell Experion PKS Serial Interface I/O Processor | MC-PSIM11 51304362-350


Only 10 left - Selling fast

PRODUCT SKU : MC-PSIM11 51304362-350

PRODUCT TYPE : I/O Processor

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell MC-PSIM11 (51304362-350) functions as a high-performance Serial Interface I/O Processor within the Honeywell Experion PKS and TDC 3000 architectures. This 100% Brand New and original module provides the critical communication bridge between the Distributed Control System (DCS) and third-party serial devices. By utilizing dual RS-232 ports, it integrates data from PLCs, weigh scales, laboratory instruments, and specialized analyzers directly into the process control network.

Technical Specifications

Feature Specification Details
Manufacturer Honeywell
Model Number MC-PSIM11
Part Number 51304362-350
Interface Ports 2 x RS-232
Maximum Baud Rate 115,200 bps
Data Bits 7 or 8
Parity None, Odd, Even
Stop Bits 1 or 2
Flow Control Hardware (RTS/CTS) or Software (XON/XOFF)
Power Input 24 VDC
Weight 0.58 kg (1.28 lbs)
Dimensions 146mm x 105mm x 27mm

Engineering Advantages

  • High-Speed Data Synchronization: The processor supports baud rates up to 115,200 bps, eliminating communication bottlenecks. This ensures real-time data refresh rates for complex serial strings, preventing lag in supervisory control loops.

  • Dual-Port Versatility: Two independent RS-232 ports allow for the simultaneous integration of two distinct serial devices. This architecture reduces the number of required I/O slots in the rack, optimizing cabinet density and lowering total hardware costs.

  • Flexible Protocol Configuration: The module accommodates various data bit and parity settings. This flexibility allows engineers to interface with a wide range of legacy and modern peripherals without requiring external protocol converters or signal conditioners.

  • Robust Flow Control: By supporting both hardware and software flow control, the MC-PSIM11 manages data buffers effectively. This prevents data overrun and packet loss during high-traffic bursts, maintaining high signal integrity for mission-critical serial links.

  • Compact Form Factor: The slim 27mm profile facilitates installation in crowded marshalling panels. It slides easily into standard Honeywell I/O chassis, ensuring secure mechanical seating and optimal electrical contact with the backplane.

FAQs

  • Can the MC-PSIM11 51304362-350 replace older MC-PSIM01 modules?

    The MC-PSIM11 (51304362-350) represents the modern hardware revision for serial processing. It typically offers backward compatibility with existing serial configurations in Experion PKS systems; however, always verify your system’s software release and firmware compatibility before performing a hot-swap.

  • Does this module support RS-485 or RS-422 signals?

    This specific model natively supports RS-232. For RS-485 or RS-422 requirements, you must utilize an external signal converter or select the corresponding Honeywell serial interface module designed for those standards.

  • How do I configure the baud rate and parity settings?

    Engineers define these parameters within the Honeywell Control Builder or the system's configuration environment. The MC-PSIM11 then downloads these settings from the controller upon initialization.

  • Is this a genuine, factory-sealed Honeywell part?

    Yes. We supply only 100% Brand New original Honeywell components. Each unit arrives in its original factory packaging with a verified serial number and carries the full manufacturer-grade reliability expected for industrial infrastructure.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering PLC Programming: Best Practices for Robust Industrial Automation

Mastering PLC Programming: Best Practices for Robust Industrial Automation

Writing clean PLC code requires discipline, especially regarding memory management. Avoid overusing SET and RESET instructions, as they often complicate debugging. If multiple rungs control the same bit, troubleshooting becomes a nightmare. Instead, focus on energizing a bit in only one location. If your logic requires complex conditions, use branches within a single rung. This approach keeps your code readable, maintainable, and significantly easier to audit during downtime.

Read more
PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

In the realm of industrial automation, distinguishing between a Programmable Logic Controller (PLC) and a Human-Machine Interface (HMI) is fundamental. While both devices work in tandem, they serve distinct purposes. The PLC acts as the "brain" of the operation, executing logic, whereas the HMI serves as the "eyes," allowing operators to monitor and interact with the system. Understanding this synergy is essential for any professional designing robust factory automation solutions.

Read more
Selecting the Right Industrial Automation Solution for Modern Manufacturing

Selecting the Right Industrial Automation Solution for Modern Manufacturing

Choosing an effective industrial automation system starts with a thorough process audit. You must identify tasks that are repetitive, labor-intensive, or prone to human error. Not every process requires high-level automation; therefore, prioritize operations that directly impact throughput and quality. By scoping your needs accurately, you avoid over-investing in unnecessary technology. A balanced approach ensures that your capital expenditure aligns with measurable gains in operational efficiency.

Read more