The Honeywell 2MLR-CPUH/T, also cataloged as the 2MLR-CPUH High Speed CPU Module, operates as a dedicated hardware component for deterministic program execution and I/O scan management within MasterLogic-200 platforms.

Hardware Specifications

Parameter Specification
Model 2MLR-CPUH/T
Brand Honeywell
Origin South Korea
Weight 0.257 kg
Dimensions Standard MasterLogic-200 CPU Module Form Factor
Operating Temp 0 to 55 deg C
Power Consumption 1173 mA at 5 VDC (internal backplane)
Program Memory 7 MB
Flash Memory 16 MB
Program Execution Methods Cyclic scan, Time-driven interrupts, Internal Memory interrupts
I/O Control Method Scan synchronous batch processing I/O (refresh method), Direct I/O method by program instruction
Programming Languages Ladder Diagram, Sequential Function Chart, Structured Text, Instruction List (view only)
Maximum I/O Capacity 31 I/O bases, 372 slots, 128,000 Network/Remote I/O points

Process Control Integration & Fieldbus Processing

The 2MLR-CPUH/T handles real-time execution of control logic across 128,000 field network and remote I/O channels. Operating via 4-20 mA HART loop protocol field devices, FOUNDATION Fieldbus, and Profibus PA network gateways integrated into the backplane chassis, the processor isolates logic execution from field noise. Internal execution routines utilize 7 MB of program RAM and 16 MB of non-volatile flash memory to deliver sub-millisecond task timing while maintaining channel-to-channel isolation and fault diagnostics.

Frequently Asked Questions

Q: What are the primary program execution methods supported by the 2MLR-CPUH/T CPU module?

A: The module executes program logic via cyclic scan processing, time-driven interrupts, and internal memory event interrupts.

Q: How does the processor handle I/O updates during execution cycles?

A: It supports both scan-synchronous batch processing (the standard memory refresh method) and direct I/O refresh triggered directly by software instructions.

Q: What is the backplane current demand for the 2MLR-CPUH/T module?

A: The unit draws a nominal current of 1173 mA from the 5 VDC backplane bus rail.

Field Installation Guidelines

  1. Isolate and disconnect all system power sources feeding the base chassis rack prior to inserting or removing the 2MLR-CPUH/T processor module.
  2. Align the rear circuit card guide pins with the backplane slot guide channels and seat the module firmly into position until top and bottom locking levers latch.
  3. Attach high-speed communication interfaces to designated front-panel connectors using shielded, twisted-pair cable assemblies.
  4. Verify that the rack mounting frame connects directly to the panel enclosure central earthing bar using a low-impedance ground wire to shield processor electronics from high-frequency interference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more