PRODUCT SKU : 51305482-205

PRODUCT TYPE : Communication Cards

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 51305482-205, also cataloged as the 51305482-205 TPNB LAN B Cable, operates as a dedicated hardware component for 100-BASE-T network applications within Experion PKS platforms.

Hardware Specifications

Parameter Specification
Model 51305482-205
Brand Honeywell
Origin USA
Weight 0.4 kg
Dimensions 7 cm x 14 cm x 14.5 cm
Operating Temp -20 to +60 deg C
Power Consumption Passive cabling assembly (Voltage handling up to 30 VAC)
Cable Spec CAT5e STP, 5 m length (+/-0.5% tolerance)
Conductor & Impedance 24 AWG stranded copper, 100 ohm +/-15%
Signal Characteristics DC resistance <= 9.38 ohm/100 m, capacitance <= 5.6 nF/100 m
Performance Metrics Propagation delay <= 548 ns/100 m, delay skew <= 45 ns/100 m

4-20 mA HART Loop & Channel-to-Channel Isolation Characteristics

Constructed with a shielded twisted-pair configuration, the assembly limits cross-talk and suppresses high-frequency electromagnetic interference along control bus pathways. Individual conductor pairs maintain low capacitance and uniform impedance, preserving channel-to-channel isolation when routed in parallel with 4-20 mA HART loop wiring harnesses. Controlled delay skew and low signal attenuation ensure deterministic frame delivery across local Ethernet nodes without degrading adjacent process I/O data channels.

Frequently Asked Questions

Q: Can the 51305482-205 cable be hot-swapped while the local node is operational?

A: Yes, physical hot-swap disconnection is supported, though network logic should account for temporary loss of LAN B communication during swapping.

Q: What is the maximum operating voltage limit for this signal cable?

A: The conductor and connector insulation rating allows signal voltage handling up to a maximum limit of 30 VAC.

Q: Does the shielding design require grounding at both ends of the run?

A: To prevent ground loop currents while maintaining noise suppression, connect the shield drain to the primary grounding terminal designated by the system panel topology.

Field Installation Guidelines

  1. Verify that the cable run length does not exceed the maximum allowed channel distance for 100-BASE-T network segments.
  2. Maintain a minimum bend radius to prevent mechanical deformation of the internal 24 AWG stranded copper pairs.
  3. Route LAN cabling through separated wireways to minimize coupling from high-voltage AC power distribution.
  4. Insert RJ45 connectors into the network interface ports until the locking tabs fully seat with a firm click.
  5. Inspect the outer jacket for physical damage and verify proper shield termination to ground terminals before energizing the system.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more