Product Overview

The Allen Bradley 2711-T10C1L1 functions as a high-capacity Human-Machine Interface (HMI) within the PanelView Standard 1000 family. This terminal features a 10-inch color active-matrix display, providing operators with a clear, centralized visualization point for complex industrial processes. We supply this unit as 100% Brand New and Original, specifically designed for systems utilizing Remote I/O (RIO) communication. It serves as a direct hardware solution for maintaining legacy control architectures without the need for extensive software migration or panel redesign.

Technical Specifications

The 2711-T10C1L1 integrates high-resolution visualization with robust industrial networking:

Feature Specification
Display Type Color Active-Matrix TFT
Display Size 10.1 inches
Resolution 640 x 480 Pixels (VGA)
Operator Input Analog Resistive Touchscreen
Communication Ports Remote I/O (RIO) and RS-232
Input Voltage 24V DC (Nominal)
Power Range 18–32V DC
Weight 6.00 lbs (2.72 kg)
Category Operator Interface (HMI)

Engineering Advantages

  • Optimized Remote I/O Connectivity: The integrated RIO port facilitates seamless connection to PLC-5, SLC 500, and ControlLogix systems over long distances. This protocol supports high-speed deterministic data exchange, ensuring real-time status updates and command execution across the plant floor.

  • Responsive Touch Interface: The analog resistive touchscreen allows precise parameter entry and screen navigation. This interface withstands industrial conditions, responding accurately even when operators wear gloves or in environments prone to surface contaminants.

  • Large-Scale Visualization: The 10-inch color display offers a significant viewing area compared to smaller HMI models. This extra space allows engineers to design detailed process mimics, multi-state indicators, and complex alarm banners that remain legible from a distance.

  • Dual-Port Versatility: In addition to the RIO network, the built-in RS-232 port supports local printing or point-to-point communication. This secondary interface simplifies data logging and localized diagnostics without interrupting the primary network traffic.

  • Direct 24V DC Integration: The unit utilizes a standard 24V DC input, aligning with modern industrial power standards. This eliminates the need for high-voltage AC lines inside the operator console, enhancing safety and reducing electromagnetic interference (EMI) near sensitive electronics.

FAQs

  • Does this unit replace the older AC-powered PanelView models?

    Yes. If you are migrating from an AC-powered version, the 2711-T10C1L1 provides the same physical footprint and Remote I/O functionality but requires a 24V DC power source. Always verify your current power supply capacity before installation.

  • What is the primary function of the RS-232 port on this RIO model?

    The RS-232 port serves primarily as a printer port or for point-to-point file transfers. It does not replace the RIO port for controller communication but adds flexibility for generating hard-copy reports or localized monitoring.

  • Is this a refurbished unit since the series is discontinued?

    No. We guarantee this 2711-T10C1L1 is 100% Brand New and Original. It arrives in its original Allen Bradley factory-sealed packaging with all security seals, UPC labels, and documentation intact.

  • How do I configure the Remote I/O rack address?

    You configure the RIO station address and baud rate through the HMI's internal configuration menu or via the PanelBuilder32 software. Ensure the settings match the scanner's configuration in your PLC or SLC processor.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more