Product Description

The Allen Bradley 2711-B6C20 is a PanelView 600 operator interface terminal from the PanelView Standard family. It combines keypad and touchscreen input for versatile operator control. With a 5-inch color TFT display, multiple communication options, and durable construction, it was widely used in industrial automation systems before being discontinued.

Technical Specifications

  • Manufacturer Allen Bradley

  • Product Line PanelView 600

  • Product Type Operator Interface Terminal

  • Part Number 2711-B6C20

  • Weight 4.25 lbs (1.93 kg)

  • Display Size 5 in.

  • Display Type Active Matrix TFT with CCF backlight

  • Display Area 115 × 87 mm (4.54 × 3.43 in.)

  • Resolution 320 × 240 pixels

  • Touchscreen Resistive, 20 × 29 pixel cell size

  • Backlight Life 100,000 hours (LED)

  • Keypad Function keys (F1–F10), cursor keys, numeric entry keys

  • Input Methods Keypad and touchscreen

  • Application Memory 240 KB

  • Communication Ports ControlNet, RS-232 (printer), Ethernet/IP

  • Input Voltage Range 85–264 V AC

  • Power Consumption 60 VA

  • Operating Temperature 0–55 °C (32–131 °F)

  • Series Compatibility A through L

  • Lifecycle Status Discontinued / Obsolete

Application Scenarios

  • Legacy operator interface for industrial automation systems

  • Monitoring and control in distributed networks with Ethernet/IP or ControlNet

  • Replacement unit for discontinued PanelView 600 terminals

FAQ

Q: What input methods does the 2711-B6C20 support?  A: Both keypad and touchscreen input.

Q: What is the display resolution?  A: 320 × 240 pixels on a 5-inch color TFT display.

Q: Is this model still in production?  A: No, it is discontinued but remains in use for legacy systems.

Comparable Models

  • 2711-B6C20: 5-inch color display with keypad/touch (this model)

  • 2711-K6C20: Keypad-only variant

  • 2711-T6C20: Touchscreen-only version

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more