Product Details

Configured for remote node signal management in Ovation DCS platforms, the Emerson 1P00028G01 (1P00028G01 Remote Node Transition Panel) provides direct physical execution of analog and digital signal interfacing. This hardware component functions as a signal transition interface to facilitate connectivity between field-side wiring and the internal Ovation system backplane architecture.

Hardware Specifications

Parameter Specification
Model 1P00028G01
Brand Emerson
Origin N/A
Weight 45 g (1.6 oz)
Dimensions 12.1 cm × 2.5 cm × 7.0 cm
Operating Temp -20 deg C to +70 deg C
Power Consumption 24 VDC nominal
I/O Resolution 12-bit or 16-bit configurable

Process Control and Signal Integrity

The transition panel maintains signal fidelity through high-resolution data conversion capabilities, supporting both 12-bit and 16-bit logic profiles. By consolidating multi-point I/O terminations within the Ovation rack assembly, the module minimizes signal attenuation and potential ground loops that can compromise loop accuracy. The design ensures consistent voltage regulation for sensitive analog inputs while providing a deterministic path for digital state monitoring across the DCS network.

Frequently Asked Questions

Q: Does the 1P00028G01 require specific backplane slot positioning within the Ovation rack?

A: The panel must be mounted within a compatible Ovation chassis slot. Ensure that the backplane connector alignment is verified prior to seating to avoid pin deformation or intermittent connection to the system bus.

Q: Is the resolution setting hardware-selectable on the module faceplate?

A: Resolution (12-bit or 16-bit) is determined by the system configuration parameters defined in the Ovation controller software. The hardware supports both modes, but performance is dependent on the downstream input/output card requirements.

Field Installation Guidelines

  • Mounting: Secure the transition panel into the designated rack or chassis space. Verify that the locking hardware is tightened to ensure mechanical stability during high-vibration operational cycles.
  • Grounding: Bond the panel chassis to the cabinet ground reference. Proper grounding is necessary to maintain signal integrity and to shield against electromagnetic interference from adjacent high-current cabling.
  • Wiring: Use shielded twisted-pair cabling for all analog signals to minimize noise pickup. Ensure cable shields are terminated at the designated grounding points and not at the signal terminals themselves to avoid ground loop current paths.
  • Verification: Check for correct 24 VDC power supply polarity before energizing the module. Monitor terminal strip contacts for signs of oxidation or looseness after initial installation and following the first thermal cycle.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more