Skip to content

What are you looking for?


You may also like

UR6TV GE Multilin Universal Relay SeriesUR6TV GE Multilin Universal Relay SeriesUR6TV GE Multilin Universal Relay Series
UR6TV GE Multilin Universal Relay Series
UR6TV GE Multilin Universal Relay Series
UR6TV GE Multilin Universal Relay Series

UR6TV GE Multilin Universal Relay Series


Only 10 left - Selling fast

PRODUCT SKU : UR6TV

PRODUCT TYPE : Digital I/O Cards

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE UR6TV, also cataloged as the UR6TV Digital I/O Module, operates as a dedicated hardware component for status monitoring and control output execution within GE Multilin Universal Relay (UR) platforms.

Hardware Specifications

Parameter Specification
Model UR6TV
Brand GE (GE Fanuc / GE Multilin)
Origin USA
Operating Temp -40 to +70 deg C (-40 to +158 deg F)
Power Consumption Powered via UR main chassis backplane
Storage Temp -40 to 85 deg C (-40 to 185 deg F)
Operating Humidity 15% to 95% non-condensing
Digital Inputs 16 discrete input channels
Digital Outputs 20 discrete output channels
Communication Direct inter-module bus integration within UR relays

Deterministic Network Real-Time Execution

The UR6TV expands the discrete point capacity of the host Multilin UR unit by processing 16 contact inputs and driving 20 relay outputs. Signal state transitions on input channels are formatted into internal data frames and distributed across high-speed backplane bus communication velocity pathways to the primary CPU.

Integration with Profinet / EtherNet/IP deterministic networks enables direct reporting of field contact states to remote control panels. Channel assignments support scalable I/O density scaling across sub-rack slots while maintaining strict firmware flash compatibility across standard GE Multilin UR software revisions.

Frequently Asked Questions

Q: What input and output contact channel densities are supported by the UR6TV module?

A: The card contains 16 discrete digital input monitoring channels alongside 20 digital output control channels.

Q: Can the UR6TV card be extracted or inserted into the Multilin UR chassis while powered?

A: No. Power to the host UR relay chassis must be completely turned off and isolated before removing or installing the module to avoid edge-connector arcing.

Q: What environmental temperature limits apply to storage and continuous operation?

A: The module is rated for continuous operation between -40 to +70 deg C (-40 to +158 deg F) and non-operating storage between -40 to 85 deg C (-40 to 185 deg F).

Field Installation Guidelines

  1. Power Isolation: Disconnect primary AC/DC auxiliary power and isolate all CT/PT voltage feeds to the Multilin UR relay frame before servicing.
  2. Electrostatic Grounding: Strap an ESD wrist band securely to a grounded metallic frame point prior to pulling the module from its card slot.
  3. Mechanical Alignment: Slide the card carefully into its assigned UR rear slot, keeping the printed circuit board aligned with the plastic internal guide rails.
  4. Fastener Seating: Push the card home until the backplane connectors join completely, then hand-tighten the top and bottom panel retaining screws.
  5. Field Terminal Wiring: Terminate discrete inputs and control output lines to the corresponding terminal blocks. Keep control wiring physically isolated from primary high-voltage bus bars.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more