Skip to content

What are you looking for?


You may also like

Multilin 820-0407/02 Digital Output Module | GEMultilin 820-0407/02 Digital Output Module | GEMultilin 820-0407/02 Digital Output Module | GE
Multilin 820-0407/02 Digital Output Module | GE
Multilin 820-0407/02 Digital Output Module | GE
Multilin 820-0407/02 Digital Output Module | GE

Multilin 820-0407/02 Digital Output Module | GE


Only 10 left - Selling fast

PRODUCT SKU : 820-0407/02

PRODUCT TYPE : Digital Output Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE Multilin 820-0407/02, also cataloged as the 820-0407 Digital Output Module, operates as a dedicated hardware component for controlled field actuation and alarm signaling within GE Multilin automation control networks.

Hardware Specifications

Parameter Specification
Model 820-0407/02
Brand GE Multilin
Origin USA
Module Type Digital Output Module
Output Channels 8 configurable digital outputs
Output Voltage 24-48 VDC
Max Output Current 500 mA per channel
Signaling Speed High-speed digital execution
Electrical Isolation Robust channel-to-logic isolation
Dimensions Standard Multilin rack slot profile
Weight 1.0 kg
Operating Temp -20 to +60 deg C
Power Consumption Rack backplane bus dependent

Backplane Bus Communication & Firmware Flash Compatibility

The digital output architecture features internal backplane bus interface logic to process actuation commands directly from the main CPU. Internal firmware flash compatibility ensures synchronized output state transitions across all 8 channels without cycle lag. Channel isolation barriers protect processing circuits from inductive transients caused by external relay coils, maintaining signal integrity across the backplane bus.

Frequently Asked Questions

Q: What are the continuous electrical load limits for each output channel?

A: Each of the 8 configurable digital output channels supports a switching voltage range of 24 to 48 VDC with a maximum load current of 500 mA per channel.

Q: How are internal control circuits isolated from field-side voltage transients?

A: Integrated galvanic isolation barriers isolate the low-voltage backplane logic from high-voltage field switching noise and inductive feedback.

Q: Is hot-swapping supported during live controller operation?

A: Module removal or insertion while the backplane bus is energized must adhere to system rack limitations; removing an active module interrupts current loop states to connected field actuators.

Field Installation Guidelines

  1. Insert the module vertically into the dedicated slot on the rack assembly, ensuring the rear backplane connectors align before pressing firmly into place.
  2. Fasten the top and bottom retention screws to secure the module to the rack chassis and establish protective earthing connections.
  3. Wire field actuators using shielded twisted-pair cables rated for the 24-48 VDC operating range.
  4. Ground cable shielding at a single point on the enclosure ground bar to prevent circulating earth ground loops.
  5. Separate digital output wiring conduits from high-voltage AC lines to prevent induced switching noise on field signal channels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more