Skip to content

What are you looking for?


You may also like

IS200STCIH6ADD | General Electric | Contact Input BoardIS200STCIH6ADD | General Electric | Contact Input BoardIS200STCIH6ADD | General Electric | Contact Input Board
IS200STCIH6ADD | General Electric | Contact Input Board
IS200STCIH6ADD | General Electric | Contact Input Board
IS200STCIH6ADD | General Electric | Contact Input Board

IS200STCIH6ADD | General Electric | Contact Input Board


Only 10 left - Selling fast

PRODUCT SKU : IS200STCIH6ADD

PRODUCT TYPE : Contact Input Boards

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for contact input signal acquisition in Mark VIe control systems, the General Electric IS200STCIH6ADD (IS200STCIH6ADD Contact Input Board) provides direct physical/electrical execution of interface connectivity between field sensors and control network I/O packs.

Hardware Specifications

Parameter Specification
Model IS200STCIH6ADD
Brand General Electric
Origin United States of America (USA)
Dimensions 15.9 cm H x 10.2 cm W
Operating Temp -30 deg C to +65 deg C
Power Consumption Not specified
Input Channels 24 contact inputs
Excitation Voltage 24, 48, 125 V dc (External)
Mounting DIN-rail or flat mounting

Industrial Control and Firmware Integration

The IS200STCIH6ADD integrates into the Mark VIe architecture to provide high-density input signal handling. The board utilizes localized noise suppression circuitry to protect against electrical surges and high-frequency interference on the 24 input channels. Firmware flash compatibility within the host I/O pack ensures that input state transitions are captured with accurate timing synchronization across the deterministic network. The I/O density scaling provided by this board allows for efficient signal mapping, supporting various field-derived contact signals while maintaining signal integrity for the control processor.

Frequently Asked Questions (FAQ)

Q: Does the IS200STCIH6ADD support hot-swapping?

A: The board serves as a passive terminal interface. While the connected I/O pack may support specific hot-swap procedures, ensure the terminal board is fully secured and properly isolated before performing maintenance on field wiring.

Q: How is the excitation voltage applied to the board?

A: The board requires an external source to provide 24, 48, or 125 V dc excitation. Field devices such as sensors or switches connect to the inputs, and the excitation voltage must be verified against the device specifications before connection.

Field Installation Guidelines

  • Mechanical Mounting: The board supports DIN-rail or flat mounting. Ensure the mounting surface is grounded to provide a path for the surge suppression circuitry to discharge transient energy.
  • Wiring and Shielding: To maintain effective noise mitigation, route contact input wiring separately from high-voltage AC lines. Utilize shielded twisted-pair cables, and terminate shield drains to the designated chassis ground terminal on the board to minimize common-mode noise.
  • Termination Torque: Ensure all terminal block connections are tightened according to standard electrical torque requirements to prevent resistive heating and intermittent signal loss.
  • Verification: After installation, verify the excitation voltage at the terminal block inputs using a calibrated multimeter. Confirm the input status within the Mark VIe HMI to ensure correct mapping of field signals to the control application.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more
Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Variable Frequency Drives (VFDs) serve as critical assets in modern industrial automation. These power electronic devices regulate electric motors by adjusting the supplied frequency and voltage. Consequently, industries utilize VFDs to reduce energy consumption and optimize process control. Major manufacturers like Siemens, ABB, and Yaskawa design highly efficient drives. However, sustained efficiency requires a rigorous preventive maintenance program.

Read more