Overview:
The IC695PNS001 is a PROFINET scanner module designed for the GE Fanuc RX3i PACSystems series. It provides robust industrial network communication with high-speed data transfer and supports multiple network topologies. This module integrates seamlessly with universal backplanes and enhances control system connectivity.

Key Features:

  • Brand: GE Fanuc Emerson

  • Model: IC695PNS001

  • Product Type: PROFINET Scanner Module

  • Series: RX3i PACSystems

  • Weight: 1.19 lbs (0.54 kg)

  • Number of Slots: 1 (single slot)

  • Backplane Support: Universal

  • Protocol Support: PROFINET

  • USB Ports: 1 × Micro USB for diagnostics and configuration

  • Internal Power: 1.1 A at 5 V DC, 1.2 A at 3.3 V DC

  • Operating Temperature: 0 to 60°C

  • Storage Temperature: -40 to 85°C

  • Ethernet Ports: 4 × Switched Ports

  • Supported Topologies: Linear, Star, Daisy chain, Redundant Media

  • LED Indicators: OK, LAN, STATUS, CONN, ORT, ACTIVE, USB

Applications:

  • Industrial Network Integration: Provides high-speed PROFINET communication for RX3i systems

  • Topology Flexibility: Supports daisy chain, star, linear, and redundant configurations

  • Control System Connectivity: Interfaces easily with multiple RX3i modules and field devices

FAQ:

  • Q: How many Ethernet ports does the module have?
    A: Four switched Ethernet ports for flexible network connections.

  • Q: Can it support redundant media topology?
    A: Yes, the module supports redundant media for high-availability networks.

  • Q: Which backplanes are compatible?
    A: Compatible with universal backplanes in RX3i systems.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Modern industrial automation relies heavily on the reliability of programmable logic controllers (PLCs). At the heart of every PLC lies its memory system. This subsystem directly dictates scan times, program capacity, and data survival during power outages. For field engineers, understanding how a control system allocates, retains, and secures this memory is essential for writing efficient code and preventing costly downtime.

Read more
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more