Skip to content

What are you looking for?


You may also like

IC660BBA026 GE Fanuc Analog Input Module for PLC SystemsIC660BBA026 GE Fanuc Analog Input Module for PLC SystemsIC660BBA026 GE Fanuc Analog Input Module for PLC Systems
IC660BBA026 GE Fanuc Analog Input Module for PLC Systems
IC660BBA026 GE Fanuc Analog Input Module for PLC Systems
IC660BBA026 GE Fanuc Analog Input Module for PLC Systems

IC660BBA026 GE Fanuc Analog Input Module for PLC Systems


Only 10 left - Selling fast

PRODUCT SKU : IC660BBA026

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview:
The IC660BBA026 from GE Fanuc is a rugged, high-precision analog input module in the Genius I/O series. Designed to support six independent analog inputs, it provides reliable 4–20mA signal acquisition with microamp resolution, ensuring precise monitoring of industrial processes. This module features user-selectable input conversion times, extensive isolation protection, and clear LED status indicators for easy diagnostics.

Key Features:

  • Six 4–20mA analog input channels

  • High-accuracy measurements with ±0.1% full-scale reading

  • Input resolution: 1 µA for precise signal capture

  • User-selectable input conversion times from 16.6ms to 400ms

  • Full channel isolation: 1500V block-to-block, 1500V group-to-group

  • Supports standard Genius Protocol communication

  • LED indicators for Unit OK and I/O Enabled

  • Heat dissipation: 12 W maximum

  • Compact and rugged design suitable for harsh industrial environments

Technical Specifications:

  • Model Number: IC660BBA026

  • Number of Inputs: 6 analog inputs

  • Points per Common: 1 group of 6

  • Output Signals: 4–20 mA

  • Supply Voltage Range: 18–56 VDC

  • Block Power: 115V AC / 125V DC

  • Input Accuracy: ±0.1% full-scale

  • Input Resolution: 1 µA

  • Input Conversion Time: 16.6–400 ms (user configurable)

  • Block-to-Block Isolation: 1500 V RMS

  • Group-to-Group Isolation: 1500 V RMS

  • Heat Dissipation: 12 W

  • Dimensions (HxWxD): 8.83 × 3.34 × 3.91 in

  • Weight: 2 lbs (0.91 kg)

  • LED Indicators: Unit OK, I/O Enabled

Applications:

  • Distributed control systems and Genius I/O networks

  • Machine automation requiring precise analog signal acquisition

  • Process monitoring in industrial environments

  • Integration with GE Fanuc PLC systems for high-reliability data input

FAQ:
Q: Is this module factory-new and original?
A: Yes, all units are original GE Fanuc products.

Q: Can the module handle harsh industrial conditions?
A: Yes, IC660BBA026 is designed for rugged environments with high isolation protection.

Q: How fast can inputs be converted?
A: Conversion times are user-selectable between 16.6 ms and 400 ms per channel.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Modern industrial automation relies heavily on the reliability of programmable logic controllers (PLCs). At the heart of every PLC lies its memory system. This subsystem directly dictates scan times, program capacity, and data survival during power outages. For field engineers, understanding how a control system allocates, retains, and secures this memory is essential for writing efficient code and preventing costly downtime.

Read more
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more