Product Details

Product Description

The IC200MDL640 is a high-reliability 16-point discrete input module from GE Fanuc, designed for use with VersaMax PLC systems. It features two isolated groups of eight inputs, offering secure signal monitoring in industrial applications. Compact and durable, this module supports straightforward DIN-rail mounting and provides efficient backplane current management.

Key Specifications

  • Manufacturer: GE Fanuc

  • Model / Part Number: IC200MDL640

  • Series: VersaMax

  • Module Type: 24VDC Discrete Input Module

  • Number of Input Points: 16 (configured as 2 groups of 8)

  • Nominal Input Voltage: 24 VDC

  • Backplane Current Consumption (5V output): 25 mA maximum

  • Thermal Derating: None required

  • Dimensions (L × W × H): 5 cm × 11 cm × 6.68 cm

  • Weight: 0.45 kg

  • Shipping Weight: 1.5 kg

Features

  • High-Density Inputs: 16 discrete points divided into two isolated groups

  • Compact Form Factor: Ideal for control panels with limited space

  • Robust Design: Ensures reliable operation under typical industrial conditions

  • LED Indicators: Provides status visibility for easier troubleshooting

  • Seamless Integration: Fully compatible with VersaMax PLC series for efficient signal monitoring

Applications

  • Suitable for discrete signal acquisition in process control and automation systems

  • Ideal for monitoring digital devices and sensors in industrial environments

FAQ / Comparison

  • Q: How does IC200MDL640 differ from IC200MDL241?
    A: IC200MDL640 operates at 24VDC and features 16 discrete points with two isolated groups, whereas IC200MDL241 is an AC input module rated for 240VAC.

  • Q: Can multiple modules be installed together?
    A: Yes, multiple IC200MDL640 modules can be installed on the same VersaMax backplane for expanded input capacity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Modern industrial automation relies heavily on the reliability of programmable logic controllers (PLCs). At the heart of every PLC lies its memory system. This subsystem directly dictates scan times, program capacity, and data survival during power outages. For field engineers, understanding how a control system allocates, retains, and secures this memory is essential for writing efficient code and preventing costly downtime.

Read more
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more