PRODUCT SKU : IC200ERM001C

PRODUCT TYPE : Bus Expansion Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE IC200ERM001C, also cataloged as the IC200ERM001 Isolated Expansion Receiver Module, operates as a dedicated hardware component for multi-rack I/O bus expansion and signal isolation within GE VersaMax control platforms.

Hardware Specifications

Parameter Specification
Model IC200ERM001C
Brand GE (GE Fanuc / Emerson)
Origin USA
Weight 0.23 kg (0.50 lbs)
Power Consumption Power sourced via backplane power supply
Max Backplane Output Voltage 5 VDC
Min Backplane Output Voltage 3.3 VDC
Expansion Connectors 2 female 26-pin D-shell ports
Rack ID Selection Onboard rotary switch
Status Indicators LEDs for Power Status and Expansion Bus Status
Mounting Location Far-left slot on VersaMax expansion rack DIN rail

Backplane Bus Communication Velocity & Deterministic Network Execution

The IC200ERM001C receives isolated expansion bus signals from an upstream expansion transmitter module (such as the ETM001) via its top 26-pin D-shell port. It rebuilds and routes local backplane voltage levels between 3.3 VDC and 5 VDC to power downstream I/O and communication modules installed on the expansion rack, optimizing backplane bus communication velocity across long distances.

The bottom female 26-pin D-shell port enables daisy-chain connections to subsequent expansion racks or accommodates an expansion bus terminator plug on the final node. Full integration into Profinet / EtherNet/IP deterministic network topologies is maintained through the primary controller interface, while strict firmware flash compatibility ensures synchronized scan execution and low-latency protocol passthrough across all extended racks.

Frequently Asked Questions

Q: What is the functional role of the rotary switch located on the IC200ERM001C module?

A: The rotary switch located under the front access door sets the unique hardware address (Rack ID) for the specific expansion rack within the system topology.

Q: How are the two 26-pin female D-shell ports utilized on the expansion receiver module?

A: The top D-shell port receives the expansion cable from the upstream transmitter or preceding receiver, while the bottom port daisy-chains to the next expansion rack or houses a bus termination plug on the final rack.

Q: Can the IC200ERM001C module be removed or inserted while the expansion rack power supply is energized?

A: No. All incoming power sources to the expansion rack and primary controller must be de-energized prior to removing or installing the module to prevent electrical damage to the expansion bus.

Field Installation Guidelines

  1. Power Shutdown: De-energize and lock out all power sources feeding the host system and the expansion rack backplane prior to installation or maintenance.
  2. Rack Position: Mount the IC200ERM001C module exclusively in the far-left slot position of the VersaMax expansion rack on the 35 mm DIN rail.
  3. Address Configuration: Set the onboard rotary switch to the assigned expansion rack ID number prior to securing the module onto the backplane carrier.
  4. Cable Interconnection: Secure the 26-pin expansion cable from the upstream transmitter into the top D-shell port using integrated thumbscrews. Attach a daisy-chain cable or terminal plug to the bottom D-shell port.
  5. Electrostatic Discharge (ESD): Wear a grounded anti-static wrist strap attached to the enclosure metallic earth during installation to protect onboard IC logic from static damage.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more