Product Details

Product Overview

The GE Fanuc IC200CPU001 is a central processing unit for the VersaMax PLC series, offering high-performance discrete I/O management and fast Boolean logic execution. With integrated communications support and battery-backed memory, it delivers reliable automation control, precise timing, and flexible connectivity for diverse industrial applications.

Technical Specifications

  • Manufacturer: GE Fanuc

  • Series: VersaMax

  • Model Number: IC200CPU001

  • Product Type: CPU Module

  • Discrete I/O Points: 2,048 inputs, 2,048 outputs

  • Internal Bits: 1,024 discrete

  • Temporary Bits: 256 discrete

  • Configurable Memory: Up to 34 KB (program, registers, analog I/O)

  • Boolean Execution Speed: 1.8 ms per K instructions (typical)

  • Built-in Communications: SNP slave, RTU slave, Serial I/O

  • Memory Storage: System flash with battery-backed RAM

  • Real-Time Clock Accuracy: 100 ppm (0.01%) or ±9 seconds/day

  • Operating Environment: Industrial-grade reliability for PLC systems

Key Features

  • High-capacity discrete I/O for complex automation tasks

  • Fast Boolean logic execution with predictable timing

  • Built-in communication protocols for networked PLC control

  • Battery-backed memory for program retention during power loss

  • Accurate internal clock for precise timing and scheduling

  • Compact CPU design compatible with VersaMax backplane

Applications

  • Central processing for factory automation and control panels

  • PLC-based machine monitoring and control systems

  • Distributed I/O integration in industrial networks

  • Process control and sequential logic automation

  • Retrofit and upgrade projects for VersaMax PLC systems

FAQ

Q1: How many discrete I/O points does the IC200CPU001 support?
It supports 2,048 discrete inputs and 2,048 discrete outputs.

Q2: Does it have built-in communication capabilities?
Yes, it includes SNP slave, RTU slave, and Serial I/O interfaces.

Q3: Is program memory retained during power loss?
Yes, system flash combined with battery-backed RAM ensures retention.

Q4: What is the Boolean execution speed?
Typical Boolean execution speed is 1.8 ms per K instructions.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Modern industrial automation relies heavily on the reliability of programmable logic controllers (PLCs). At the heart of every PLC lies its memory system. This subsystem directly dictates scan times, program capacity, and data survival during power outages. For field engineers, understanding how a control system allocates, retains, and secures this memory is essential for writing efficient code and preventing costly downtime.

Read more
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more