Skip to content

What are you looking for?


You may also like

General Electric DS200RTBAG2AHC Relay Terminal BoardGeneral Electric DS200RTBAG2AHC Relay Terminal BoardGeneral Electric DS200RTBAG2AHC Relay Terminal Board
General Electric DS200RTBAG2AHC Relay Terminal Board
General Electric DS200RTBAG2AHC Relay Terminal Board
General Electric DS200RTBAG2AHC Relay Terminal Board

General Electric DS200RTBAG2AHC Relay Terminal Board


Only 10 left - Selling fast

PRODUCT SKU : DS200RTBAG2AHC

PRODUCT TYPE : Relay Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for relay-based signal interfacing within Mark V Speedtronic control systems, the GE DS200RTBAG2AHC (DS200RTBAG2 Relay Terminal Board) provides direct physical electrical switching for LAN and remote I/O control applications.

Hardware Specifications

Parameter Specification
Model DS200RTBAG2AHC
Brand General Electric
Origin USA
Weight 0.8 kg
Dimensions 16 cm x 16 cm x 12 cm
Operating Temp Not specified
Power Consumption 24 VDC (coil voltage)
Core Components 7 DPDT (Form-C) relays, 3 4PDT relays, 10 MOV surge protectors

Industrial Control & Firmware Compatibility

The DS200RTBAG2AHC functions as a passive interface module, requiring no firmware flash compatibility as it contains no logic-based software. Operational parameters are governed by board-level jumper configurations via berg-type jumper pins, which must be aligned with site-specific I/O requirements to ensure deterministic relay state execution. Backplane bus communication velocity is managed through the host interface, while the onboard diagnostic lamps provide real-time status indication of relay coil activation. The board utilizes MOV protection (130 V AC) for each relay to mitigate surge-induced damage, ensuring the module maintains its signal-switching integrity under inductive loading conditions.

Frequently Asked Questions

Q: Are the MOVs on the relay terminal board field-replaceable?

A: Yes. Each of the ten relays is protected by a 130 V AC metal oxide varistor (MOV). If a surge event occurs, these components are designed to be removed and replaced individually to restore relay protection without requiring a full board replacement.

Q: How do I select the correct relay terminal board for my application?

A: Selection is based on required coil voltage. The DS200RTBAG2AHC is rated for 24 VDC. For 110 VDC applications, specify the RTBAG1 board; for 115 VAC applications, specify the RTBAG3 board.

Field Installation Guidelines

  • Relay Protection: Ensure that the MOVs are properly seated and intact prior to power-up. Damaged MOVs can lead to premature failure of the DPDT or 4PDT relay contacts due to high-voltage transients during inductive load switching.
  • Jumper Configuration: Verify all berg-type jumper pin settings against the installation manual before initial energization. Incorrect jumper placement can lead to improper relay logic or feedback failures on the LAN/remote I/O circuit.
  • Connector Integrity: The board features two stab connectors, one 16-pin connector, and one 2-pin inter-board connector. Ensure these are free of debris and fully engaged to prevent intermittent signal paths that could cause relay "chatter" or false state reporting.
  • Shielding and Grounding: When terminating field wires, ensure proper cable management to avoid mechanical stress on the PCB. Verify that the cabinet ground connection is robust, as this board serves as a centralized relay termination point for sensitive control signals.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more
Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Variable Frequency Drives (VFDs) serve as critical assets in modern industrial automation. These power electronic devices regulate electric motors by adjusting the supplied frequency and voltage. Consequently, industries utilize VFDs to reduce energy consumption and optimize process control. Major manufacturers like Siemens, ABB, and Yaskawa design highly efficient drives. However, sustained efficiency requires a rigorous preventive maintenance program.

Read more