Skip to content

What are you looking for?


You may also like

GE IC200MDL243 | 16-Point AC Isolated Input Module for VersaMaxGE IC200MDL243 | 16-Point AC Isolated Input Module for VersaMaxGE IC200MDL243 | 16-Point AC Isolated Input Module for VersaMax
GE IC200MDL243 | 16-Point AC Isolated Input Module for VersaMax
GE IC200MDL243 | 16-Point AC Isolated Input Module for VersaMax
GE IC200MDL243 | 16-Point AC Isolated Input Module for VersaMax

GE IC200MDL243 | 16-Point AC Isolated Input Module for VersaMax


Only 10 left - Selling fast

PRODUCT SKU : IC200MDL243

PRODUCT TYPE : Isolated Input Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IC200MDL243 is a high-performance 16-point AC isolated input module from GE Fanuc, engineered for precise monitoring and reliable control of industrial processes. Designed for seamless integration with VersaMax controllers, it offers robust isolation, compact installation, and clear status indication for each input channel.

Key Features and Specifications

  • Model: IC200MDL243

  • Manufacturer: GE Fanuc

  • Series: VersaMax

  • Module Type: Discrete AC Isolated Input

  • Number of Inputs: 16 isolated AC channels

  • Nominal Voltage: 120 VAC

  • Input Voltage Range: 0–132 VAC (47–63 Hz)

  • On-State Voltage: 70–132 VAC

  • Off-State Voltage: 0–20 VAC

  • Minimum On-State Current: 5 mA

  • Maximum Off-State Current: 2.5 mA

  • Input Impedance: 8.6 kΩ reactive at 60 Hz (typical)

  • Isolation Ratings: 250 VAC continuous, 1500 VAC for 1 minute

  • LED Indicators: Individual green LEDs for each input, plus OK LED for backplane power

  • Backplane Current Draw: 100 mA maximum

  • Operating Temperature: -40°C to 60°C

  • Power Supply Requirement: 24 V DC

Additional Features

  • High-Density Inputs: Provides comprehensive monitoring with 16 isolated points

  • Robust Safety: Fully isolated inputs ensure operational safety and prevent signal interference

  • Compact Footprint: Designed for tight panel spaces

  • Compatibility: Works with all VersaMax PLC controllers for reliable automation integration

Applications

  • Use Case: Suitable for industrial control panels, process monitoring, and signal acquisition in high-voltage environments

  • Ideal For: Systems requiring clear LED feedback for each input channel

FAQ / Comparison

  • Q: How does IC200MDL243 differ from IC200MDL241?
    A: IC200MDL243 provides isolated inputs at 120 VAC, while IC200MDL241 is typically designed for 240 VAC non-isolated AC inputs.

  • Q: Can it operate in mixed I/O configurations?
    A: Yes, it can be combined with other VersaMax input/output modules, including discrete outputs and mixed I/O modules.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Modern industrial automation relies heavily on the reliability of programmable logic controllers (PLCs). At the heart of every PLC lies its memory system. This subsystem directly dictates scan times, program capacity, and data survival during power outages. For field engineers, understanding how a control system allocates, retains, and secures this memory is essential for writing efficient code and preventing costly downtime.

Read more
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more