Skip to content

What are you looking for?


You may also like

IC200CPU002 GE Fanuc VersaMax PLC CPU ModuleIC200CPU002 GE Fanuc VersaMax PLC CPU ModuleIC200CPU002 GE Fanuc VersaMax PLC CPU Module
IC200CPU002 GE Fanuc VersaMax PLC CPU Module
IC200CPU002 GE Fanuc VersaMax PLC CPU Module
IC200CPU002 GE Fanuc VersaMax PLC CPU Module

IC200CPU002 GE Fanuc VersaMax PLC CPU Module


Only 10 left - Selling fast

PRODUCT SKU : IC200CPU002

PRODUCT TYPE : PLC CPU Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The GE Fanuc IC200CPU002 is a high-performance CPU module for the VersaMax PLC series, providing efficient processing, reliable memory retention, and robust communication support. Its compact design supports both RS-232 and RS-485 serial interfaces, offering flexibility for industrial control applications. The module includes a user-friendly Run/Stop switch for convenient operation and supports a 42 KB memory for program and data storage.

Technical Specifications

  • Manufacturer: GE Fanuc

  • Series: VersaMax

  • Model Number: IC200CPU002

  • Product Type: CPU Module

  • Weight: 1.0 lbs (0.45 kg)

  • Operating Voltage: 5 V DC

  • Memory Capacity: 42 KB for programs, registers, and I/O data

  • Serial Communication Ports: RS-232, RS-485

  • Control Switch: Run / Stop for manual operation

  • Form Factor: Compact module compatible with VersaMax backplane

  • Operating Environment: Industrial-rated for reliable PLC operation

Key Features

  • 42 KB memory for program and data storage

  • Dual serial ports for flexible network integration (RS-232, RS-485)

  • User-friendly Run/Stop switch for manual control

  • Compact CPU design optimized for VersaMax systems

  • Reliable operation under industrial conditions

Applications

  • Core processor for VersaMax PLC automation

  • Machine control panels and distributed I/O systems

  • Industrial process control and sequential logic automation

  • PLC retrofit or upgrade projects

FAQ

Q1: What type of serial communications does IC200CPU002 support?
It supports both RS-232 and RS-485 interfaces for flexible network connections.

Q2: How much memory does the CPU module provide?
It includes 42 KB of memory for programs, registers, and I/O data.

Q3: Does it have a manual control switch?
Yes, the module features a Run/Stop switch for convenient operation.

Q4: Is it compatible with VersaMax PLC series?
Yes, it is fully compatible with VersaMax backplane and I/O modules.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Modern industrial automation relies heavily on the reliability of programmable logic controllers (PLCs). At the heart of every PLC lies its memory system. This subsystem directly dictates scan times, program capacity, and data survival during power outages. For field engineers, understanding how a control system allocates, retains, and secures this memory is essential for writing efficient code and preventing costly downtime.

Read more
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more