Skip to content

What are you looking for?


You may also like

GE Fanuc IC695ETM001-ER Ethernet Interface Module for PACSystemsGE Fanuc IC695ETM001-ER Ethernet Interface Module for PACSystemsGE Fanuc IC695ETM001-ER Ethernet Interface Module for PACSystems
GE Fanuc IC695ETM001-ER Ethernet Interface Module for PACSystems
GE Fanuc IC695ETM001-ER Ethernet Interface Module for PACSystems
GE Fanuc IC695ETM001-ER Ethernet Interface Module for PACSystems

GE Fanuc IC695ETM001-ER Ethernet Interface Module for PACSystems


Only 10 left - Selling fast

PRODUCT SKU : IC695ETM001

PRODUCT TYPE : Ethernet Interface Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The IC695ETM001-ER from GE Fanuc is a high-performance Ethernet interface module designed for PACSystems RX3i and Series 90-30 systems. It provides reliable, high-speed communication for industrial control applications, supporting both Ethernet and serial protocols.

Key Technical Specifications

  • Brand: GE Fanuc

  • Model / Part Number: IC695ETM001-ER

  • Module Type: Ethernet Interface Module

  • Slots Required: Single slot

  • Processing Speed: 200 MHz

  • Bus Speed: 10/100 Mbaud

  • Communication Ports: 2 RJ-45 Ethernet ports

  • Supported Protocols: SRT, Modbus TCP, Ethernet Global Data (EGD)

  • Serial Connectivity: RS-232 via Station Manager

  • Mounting: DIN rail or panel mount compatible

Features and Functionality

  • Supports multiple network protocols for flexible integration

  • Dual RJ-45 ports for redundancy or network segmentation

  • High-speed processing for real-time industrial communication

  • Compact single-slot design for space-efficient installations

Applications

  • Industrial networking and data exchange

  • Remote I/O integration for PACSystems RX3i and Series 90-30

  • Modbus TCP and EGD-based control and monitoring

  • Redundant or multi-network communication setups

Environmental and Installation Info

  • Operating Temperature: 0°C to 60°C

  • Storage Temperature: -40°C to 85°C

  • Designed for robust industrial environments with reliable connectivity

Similar Module Comparison

  • Compared with IC695ETM001, the IC695ETM001-ER adds extended protocol support and higher processing efficiency.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Modern industrial automation relies heavily on the reliability of programmable logic controllers (PLCs). At the heart of every PLC lies its memory system. This subsystem directly dictates scan times, program capacity, and data survival during power outages. For field engineers, understanding how a control system allocates, retains, and secures this memory is essential for writing efficient code and preventing costly downtime.

Read more
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more