Configured for high-precision rotor feedback processing in Mark V control systems, the General Electric DS200LRPBG1AAA (DS200LRPBG1AAA Resolver Board) provides direct physical/electrical execution of rotary transformer signal digitization and system interface.

Hardware Specifications

Parameter Specification
Model DS200LRPBG1AAA
Brand General Electric
Origin United States of America (USA)
Input Type Analog resolver (rotary transformer)
Output Type Digitized position/speed data

Industrial Control and Drive Systems

The DS200LRPBG1AAA leverages backplane bus communication velocity to transmit digitized rotor dynamics data to host controllers. The board supports firmware flash compatibility, facilitating refined signal processing algorithms for speed and position feedback loops. Through integrated I/O density scaling, the module converts raw analog inputs into deterministic data formats, essential for synchronizing motor control and turbine management functions. The board architecture includes localized signal refinement circuits and dedicated diagnostic LED indicators that map directly to status registers within the drive control network.

Frequently Asked Questions (FAQ)

Q: How does the board interface with the resolver hardware?

A: The board receives raw analog excitation and feedback signals from the rotary transformer (resolver). Internal microprocessors perform the signal conversion and digitization, preparing the data for transmission to the Mark V control system.

Q: What is the primary purpose of the onboard LED indicators?

A: The diagnostic LEDs provide real-time visual status of the board's operational health, allowing field technicians to identify signal loss, conversion errors, or internal hardware faults without requiring external diagnostic tools.

Field Installation Guidelines

  • Signal Shielding: Resolver signals are sensitive to electromagnetic interference (EMI). Ensure that shielded twisted-pair cables are used for all resolver-to-board connections and that the shield is grounded at a single, clean instrumentation ground point to minimize crosstalk.
  • Connector Integrity: Verify that all cabling connected to the I/O terminals is fully seated. Given the high-frequency nature of resolver signal excitation, any loose connection will result in noise or inaccurate position feedback, potentially causing control instability.
  • Mounting: Ensure the board is securely fastened within the Mark V rack. Vibration can induce mechanical stress on the signal conversion components, leading to drift in the digitized position signal.
  • Grounding: Verify that the rack chassis provides a low-impedance path to the system ground. This is necessary for the stability of the analog-to-digital conversion circuits and to maintain the integrity of the diagnostic status indicators.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more
Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Variable Frequency Drives (VFDs) serve as critical assets in modern industrial automation. These power electronic devices regulate electric motors by adjusting the supplied frequency and voltage. Consequently, industries utilize VFDs to reduce energy consumption and optimize process control. Major manufacturers like Siemens, ABB, and Yaskawa design highly efficient drives. However, sustained efficiency requires a rigorous preventive maintenance program.

Read more