Skip to content

What are you looking for?


You may also like

GE 977-0089/12 D20 M+ Cable AssemblyGE 977-0089/12 D20 M+ Cable AssemblyGE 977-0089/12 D20 M+ Cable Assembly
GE 977-0089/12 D20 M+ Cable Assembly
GE 977-0089/12 D20 M+ Cable Assembly
GE 977-0089/12 D20 M+ Cable Assembly

GE 977-0089/12 D20 M+ Cable Assembly


Only 10 left - Selling fast

PRODUCT SKU : 977-0089/12

PRODUCT TYPE : Cable Assemblies

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE 977-0089/12, also cataloged as the 977-0089/12 Cable Assembly, operates as a dedicated hardware component for internal data interconnections and signal routing within D20 M+ substation controller racks.

Hardware Specifications

Parameter Specification
Model 977-0089/12
Brand GE / GE Fanuc
Origin USA
Weight 0.05 kg (0.10 lbs)
Dimensions Length 304.8 mm (12 in)
Operating Temp -20 to +70 deg C
Power Consumption Passive Cable Assembly (0 W Base Draw)
Cable Type Multi-Conductor Ribbon Cable Assembly
System Compatibility GE D20 M+ Substation Controller Platform
Cross-Reference 977-0089/18 (18-Inch Variant)

Backplane Bus Communication Velocity and Signal Integrity

The 977-0089/12 cable assembly routes internal digital signals between adjacent D20 M+ system cards without introducing propagation delays. High-density conductor construction preserves backplane bus communication velocity across expanded controller configurations. Shielded line geometries prevent high-frequency noise coupling, maintaining firmware flash compatibility and deterministic data execution across I/O expansion racks.

Frequently Asked Questions

Q: Can the 977-0089/12 cable assembly be hot-swapped while the D20 M+ system is energized?

A: No. Power to the sub-rack segment must be de-energized prior to disconnecting or plugging in the cable assembly to prevent signal glitches or connector pin damage.

Q: What is the main functional difference between the 977-0089/12 and the 977-0089/18 cable assembly?

A: The physical length. The 977-0089/12 measures 12 inches (304.8 mm), whereas the 977-0089/18 variant provides an 18-inch reach for wider cabinet layouts.

Field Installation Guidelines

  1. Isolate and de-energize panel power to the target D20 M+ sub-rack before installation.
  2. Inspect cable connector pins and locking latches for physical damage or misalignment.
  3. Align keyed connector headers strictly with board receptacles to ensure proper pin orientation.
  4. Push connectors fully into place until side locking tabs snap into locked position.
  5. Maintain minimum bend radii along the ribbon body to avoid conductor fatigue and trace degradation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more