Skip to content

What are you looking for?


You may also like

DS200DACAG1ACD AC/DC Power Conversion Module | General ElectricDS200DACAG1ACD AC/DC Power Conversion Module | General ElectricDS200DACAG1ACD AC/DC Power Conversion Module | General Electric
DS200DACAG1ACD AC/DC Power Conversion Module | General Electric
DS200DACAG1ACD AC/DC Power Conversion Module | General Electric
DS200DACAG1ACD AC/DC Power Conversion Module | General Electric

DS200DACAG1ACD AC/DC Power Conversion Module | General Electric


Only 10 left - Selling fast

PRODUCT SKU : DS200DACAG1ACD

PRODUCT TYPE : Power Supply Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for power regulation and energy storage in Mark V Speedtronic systems, the GE DS200DACAG1ACD (DS200DACA Power Conversion Module) provides direct physical execution of AC to DC voltage conversion.

Hardware Specifications

Parameter Specification
Model DS200DACAG1ACD
Brand General Electric
Origin USA
Operating Temp -30 deg C to 60 deg C
Power Consumption 1000 W (Output rating)
Core Performance 105-132 V AC input, 90-145 V DC output, 9.5 A DC max

Industrial Control & Firmware Compatibility

The DACA module maintains system-wide operational continuity by facilitating local energy storage to extend ride-through time during control power loss. I/O density scaling and parallel operation capabilities are defined by the module revision; while this specific unit functions as a primary converter, newer variants allow for paralleling to increase output current capacity. Firmware flash compatibility is not required, as the conversion logic is handled by internal switching circuitry. System integration requires precise configuration of the internal cable taps (JTX1 for 115 V AC or JTX2 for 230 V AC) to match the facility supply, ensuring deterministic voltage regulation for the 125 V DC control bus.

Frequently Asked Questions

Q: How is the input voltage range selected for this module?

A: Input voltage selection is performed via internal cable configuration. The internal cable must be plugged into connector JTX1 for 115 V AC operations or JTX2 for 230 V AC operations prior to energizing the unit.

Q: Is this module capable of parallel operation to increase output current?

A: Paralleling is generally not recommended for this specific revision. Paralleling capabilities were introduced in later model iterations of the DACA series. Refer to system-level documentation to verify if your specific control architecture supports redundant power supplies.

Field Installation Guidelines

  • Mounting Stability: Secure the module using the four mounting holes provided in the base. Ensure the chassis is properly bonded to the cabinet ground to manage transient voltages and heat dissipation.
  • Connector Integration: Utilize the JZ 12-position connector for AC input and DC output. This must be mated securely with the PDM (Power Distribution Module) connector JZ2 or JZ3. Ensure the latching mechanism is fully engaged to prevent vibration-induced disconnection.
  • Polarity Verification: Confirm the DC output polarity matches the system control bus requirements before finalizing connections. Reverse polarity can cause immediate damage to connected control electronics.
  • Thermal Environment: The module operates across a wide temperature range (-30 to 60 deg C). Ensure adequate ventilation is maintained around the module to prevent premature failure of internal electrolytic capacitors, which are critical for the local energy storage/ride-through function.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more
Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Variable Frequency Drives (VFDs) serve as critical assets in modern industrial automation. These power electronic devices regulate electric motors by adjusting the supplied frequency and voltage. Consequently, industries utilize VFDs to reduce energy consumption and optimize process control. Major manufacturers like Siemens, ABB, and Yaskawa design highly efficient drives. However, sustained efficiency requires a rigorous preventive maintenance program.

Read more