Skip to content

What are you looking for?


You may also like

IS220YDIAS1AK GE Mark VIe Discrete Contact Input ModuleIS220YDIAS1AK GE Mark VIe Discrete Contact Input ModuleIS220YDIAS1AK GE Mark VIe Discrete Contact Input Module
IS220YDIAS1AK GE Mark VIe Discrete Contact Input Module
IS220YDIAS1AK GE Mark VIe Discrete Contact Input Module
IS220YDIAS1AK GE Mark VIe Discrete Contact Input Module

IS220YDIAS1AK GE Mark VIe Discrete Contact Input Module


Only 10 left - Selling fast

PRODUCT SKU : IS220YDIAS1AK

PRODUCT TYPE : Discrete Input Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE IS220YDIAS1AK, also cataloged as the IS220YDIA Discrete Contact Input I/O Module, operates as a dedicated hardware component for discrete contact status monitoring within Mark VIe control system networks.

Hardware Specifications

Parameter Specification
Model IS220YDIAS1AK
Brand General Electric
Origin USA
Weight 0.91 kg (2 lbs)
Dimensions 138 x 86 x 56 mm
Operating Temp -30 to 65 deg C
Power Consumption 18 to 32 VDC input supply
System Series Mark VIe
Onboard Memory 256 MB DDR SDRAM
Operating System QNX Neutrino
Software Compatibility ControlST V04.03.18C
Relative Humidity 5% to 95% (non-condensing)

Backplane Bus Communication Velocity and Firmware Flash Compatibility

Powered by the QNX Neutrino real-time operating system and 256 MB of DDR SDRAM, the IS220YDIAS1AK maintains high backplane bus communication velocity across dual IONet Ethernet interfaces. The module digitizes optical and contact sensor inputs, applying noise filtering and sequence-of-events (SOE) timestamping at the hardware layer. Dedicated internal memory architectures ensure full firmware flash compatibility through GE ControlST management software, allowing online flash updates without disturbing adjacent I/O packs on the terminal board.

Frequently Asked Questions

Q: What operating system and memory architecture power the IS220YDIAS1AK module?

A: The module operates on the QNX Neutrino real-time operating system utilizing 256 MB of onboard DDR SDRAM.

Q: What power supply range is required for module operation?

A: The module operates within an input supply range of 18 VDC to 32 VDC.

Q: How is firmware maintained on the IS220YDIAS1AK?

A: The module features firmware flash compatibility managed directly through GE ControlST V04.03.18C or compatible system software.

Field Installation Guidelines

Isolate power to the field terminal board before attaching or removing the IS220YDIAS1AK I/O pack. Maintain electrostatic discharge (ESD) protection by using a grounded wrist strap attached to the metal cabinet frame. Align the module connectors with the matching terminal board interface, push firmly until fully seated, and secure the mechanical retaining screws to establish ground continuity. Connect Ethernet network lines to the designated IONet ports before energizing the 24 VDC power feed.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.

Read more
Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Precision motion control systems drive high-throughput manufacturing across modern industrial automation environments. Unlike standard induction motors running on basic variable frequency drives, servo motor systems deliver sub-millimeter positioning accuracy and fast dynamic response.

Read more