Skip to content

What are you looking for?


You may also like

GE IS215WEPAH2AB Mark VIe Circuit BoardGE IS215WEPAH2AB Mark VIe Circuit BoardGE IS215WEPAH2AB Mark VIe Circuit Board
GE IS215WEPAH2AB Mark VIe Circuit Board
GE IS215WEPAH2AB Mark VIe Circuit Board
GE IS215WEPAH2AB Mark VIe Circuit Board

GE IS215WEPAH2AB Mark VIe Circuit Board


Only 10 left - Selling fast

PRODUCT SKU : IS215WEPAH2AB

PRODUCT TYPE : Printed Circuit Boards

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE IS215WEPAH2AB, also cataloged as the IS215WEPA Circuit Board, operates as a dedicated hardware component for high-speed digital/analog signal acquisition and protocol routing within GE Mark VIe Control Systems.

Hardware Specifications

Parameter Specification
Model IS215WEPAH2AB
Brand GE / General Electric
Origin USA
Dimensions 150 mm x 100 mm x 40 mm
Operating Temp -20 to 60 deg C
Power Consumption Board Supply Input 24 VDC (+/-10%)
Processor Dual-core, 1.2 GHz
Memory 2 GB RAM, 8 GB Flash
Digital I/O Channels 16 Digital Channels
Analog I/O Channels 8 Analog Channels
Communication Protocols Ethernet, Modbus TCP/IP

Backplane Bus Communication Velocity and Firmware Flash Compatibility

Powered by an onboard 1.2 GHz dual-core processor and 2 GB RAM, the IS215WEPAH2AB handles local Modbus TCP/IP communication and real-time I/O channel processing directly at the module layer. Offloading signal conversion across its 16 digital and 8 analog channels preserves backplane bus communication velocity across the Mark VIe cabinet backplane. The onboard 8 GB flash non-volatile memory provides secure parameter storage and maintains firmware flash compatibility during controller system updates and card maintenance.

Frequently Asked Questions

Q: What power input constraints apply to energizing the IS215WEPAH2AB circuit board?

A: The board requires a regulated 24 VDC power supply operating within a +/-10% voltage tolerance range.

Q: How are firmware and configuration parameters retained on the module during power cycles?

A: Configuration data and system firmware are stored in onboard 8 GB flash non-volatile memory, preserving system parameters independently of external backplane power.

Q: What environmental and industry standards govern the operation of this board?

A: The IS215WEPAH2AB is rated for ambient temperatures from -20 to 60 deg C and complies with UL, CE, and IEC 61850-3 standards for industrial power system environments.

Field Installation Guidelines

  1. Isolate all 24 VDC auxiliary power sources and external field instrument loops prior to installing or removing the card.
  2. Wear an ESD wrist strap attached to cabinet frame earth ground to prevent static damage to sensitive surface-mount components.
  3. Slide the 150 mm x 100 mm x 40 mm board assembly into the designated enclosure slot guides until backplane connectors interlock completely.
  4. Fasten all mechanical retention screws to ensure stable physical chassis grounding and shield bonding.
  5. Terminate analog and digital field wiring using shielded twisted-pair cables, ensuring shield drains ground at a single common enclosure terminal.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

In industrial automation, variable frequency drives (VFDs) regulate motor speed and torque across manufacturing plants and material handling systems. However, certain heavy-duty applications experience external loads that can rotate the motor shaft without an active command. For instance, gravity pulls loads downward in unanchored hoisting equipment. Therefore, engineers integrate mechanical brakes with VFD logic to maintain absolute safety and prevent structural damage or personnel injury during shutdowns.

Read more
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.