Skip to content

What are you looking for?


You may also like

ANB10D-410 | Yokogawa Duplicated Node Interface Unit (NIU)ANB10D-410 | Yokogawa Duplicated Node Interface Unit (NIU)ANB10D-410 | Yokogawa Duplicated Node Interface Unit (NIU)
ANB10D-410 | Yokogawa Duplicated Node Interface Unit (NIU)
ANB10D-410 | Yokogawa Duplicated Node Interface Unit (NIU)
ANB10D-410 | Yokogawa Duplicated Node Interface Unit (NIU)

ANB10D-410 | Yokogawa Duplicated Node Interface Unit (NIU)


Only 10 left - Selling fast

PRODUCT SKU : ANB10D-410

PRODUCT TYPE : Node Interface Unit

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The ANB10D-410 is designed for dual-redundant configurations, ensuring high availability in demanding industrial environments. It facilitates the expansion of I/O modules, allowing the DCS to interface with a wide range of field sensors and actuators while maintaining signal integrity over long distances.

Technical Specifications

  • Model Code: ANB10D (Node Interface Unit for Dual-Redundant ESB Bus)

  • Suffix Code -410:

    • 4: Dual-redundant power supply

    • 1: 100-120 V AC power supply

    • 0: Basic type

  • Mounting: 19-inch rack mountable

  • Communication: Dual ESB bus interface

  • Power Consumption: Approximately 100 VA

  • Weight: Approximately 10 kg (fully loaded with power supply units)

Key Features

  • High Reliability: Supports dual-redundant power supplies and communication cables to prevent system downtime in case of a single point of failure.

  • Seamless Integration: Designed specifically for Yokogawa’s proprietary RIO (Remote I/O) and FIO (Field I/O) architectures.

  • Hot-Swappable: Supports the replacement of interface modules without interrupting the operation of the remaining system.

  • Condition Monitoring: Built-in diagnostics provide real-time status updates on power supply health and bus communication quality.

Application and Usage

This unit is typically installed in cabinet assemblies where high-density I/O processing is required. It is commonly used in:

  • Oil & Gas Refineries: Managing large-scale sensor arrays.

  • Chemical Processing: Handling complex control loops with high redundancy requirements.

  • Power Plants: Ensuring stable communication between distributed control nodes and the central station.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more