Emerson EPRO PR9268/302-100 Electrodynamic Velocity Sensor
Emerson EPRO PR9268/302-100 Electrodynamic Velocity Sensor

Emerson EPRO PR9268/302-100 Electrodynamic Velocity Sensor


Only 10 left - Selling fast

PRODUCT SKU : PR9268/302-100

PRODUCT TYPE : Vibration Sensors

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for vibration monitoring in rotating machinery, the Emerson EPRO PR9268/302-100 (PR9268/302-100) Electrodynamic Velocity Sensor provides direct physical execution of seismic vibration signal acquisition.

Suffix Breakdown & Model Matrix

Model Suffix Orientation Sensitivity Frequency Range
PR9268/01x-x00 Omni Directional 17.5 mV/mm/s 14-1000 Hz
PR9268/20x-x00 Vertical +/- 60 deg 28.5 mV/mm/s 4-1000 Hz
PR9268/30x-x00 Horizontal +/- 30 deg 28.5 mV/mm/s 4-1000 Hz
PR9268/60x-000 Vertical +/- 30/60 deg 22.0 mV/mm/s 10-1000 Hz
PR9268/70x-000 Horizontal +/- 10/30 deg 22.0 mV/mm/s 10-1000 Hz

Hardware Specifications

Parameter Specification
Model PR9268/302-100
Brand Emerson EPRO
Operating Temp Standard industrial range
Power Consumption Passive (no external power)
Sensitivity 28.5 mV/mm/s
Max Acceleration 10 g (continuous), 20 g (intermittent)

Process Control and DCS Connectivity

The PR9268 series sensors are designed for integration with process control systems utilizing 4-20 mA HART loop protocol standards for long-distance signal transmission. To ensure measurement integrity, channel-to-channel isolation must be maintained within the input interface of the monitoring system to prevent ground loops that could introduce signal drift. Cold junction compensation (CJC) is not required for these electrodynamic components; however, impedance matching between the sensor's coil and the signal conditioner is necessary to ensure the frequency response remains within the rated 4-1000 Hz window.

Frequently Asked Questions

Q: Does the orientation affect the sensitivity of the sensor?

A: Yes. Electrodynamic sensors utilize a mass-spring system where the natural frequency is dependent on gravity. Installing the sensor outside the specified orientation range (e.g., +/- 30 deg for the PR9268/30x-x00) will result in measurement errors and potential damage to the internal suspension mechanism.

Q: Can this sensor be used in areas with high-intensity electromagnetic interference?

A: Electrodynamic sensors generate an output signal via coil induction. While they are resilient, utilize shielded twisted-pair cabling and ensure the shield is grounded at the signal conditioner input to minimize induced noise in industrial environments.

Field Installation Guidelines

  1. Mount the sensor on a machined, flat surface on the machinery casing to ensure high-frequency coupling.
  2. Verify the orientation of the sensor matches the suffix requirement (e.g., horizontal for PR9268/30x-x00); incorrect mounting angle will shift the natural frequency and distort the vibration amplitude.
  3. Torque the mounting stud/bolt to the manufacturer's recommendation to prevent structural resonance between the sensor and machine casing.
  4. Route cabling away from high-power AC lines to prevent magnetic induction into the velocity coil circuit.
  5. Perform a bump test or verify baseline vibration levels during initial startup to confirm that the sensor is within its dynamic range and that the signal conditioner is correctly calibrated to the 28.5 mV/mm/s sensitivity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

In industrial automation, variable frequency drives (VFDs) regulate motor speed and torque across manufacturing plants and material handling systems. However, certain heavy-duty applications experience external loads that can rotate the motor shaft without an active command. For instance, gravity pulls loads downward in unanchored hoisting equipment. Therefore, engineers integrate mechanical brakes with VFD logic to maintain absolute safety and prevent structural damage or personnel injury during shutdowns.

Read more
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.

Read more