Skip to content

What are you looking for?


You may also like

Emerson VE4002S1T2B3 Discrete Output ModuleEmerson VE4002S1T2B3 Discrete Output ModuleEmerson VE4002S1T2B3 Discrete Output Module
Emerson VE4002S1T2B3 Discrete Output Module
Emerson VE4002S1T2B3 Discrete Output Module
Emerson VE4002S1T2B3 Discrete Output Module

Emerson VE4002S1T2B3 Discrete Output Module


Only 10 left - Selling fast

PRODUCT SKU : VE4002S1T2B3

PRODUCT TYPE : Discrete Output Modules

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete signal execution in DeltaV control platforms, the Emerson VE4002S1T2B3 (VE4002S1T2B3 Discrete Output Module) provides direct physical/electrical control via 8 high-side output channels.

Hardware Specifications

Parameter Specification
Model VE4002S1T2B3
Brand Emerson
Origin Not specified
Weight 3.00 lbs
Power Consumption 24 VDC
Channel Count 8 Channels

Process Control and DCS Connectivity

The VE4002S1T2B3 module utilizes channel-to-channel isolation to prevent propagation of electrical faults between individual output circuits. This design ensures that a localized short circuit or overcurrent condition on one channel does not compromise the operational integrity of remaining channels. Integration with the DeltaV control network is managed through the I/O bus, which provides real-time status feedback for each discrete point. The architecture supports 4-20 mA HART loop protocol compatibility on associated analog channels within the same I/O subsystem, ensuring consistent field instrumentation diagnostics across the process environment.

Frequently Asked Questions

Q: Does the module support hot-swapping under power?

A: Yes, this module is designed for insertion and removal while the I/O subsystem is energized (hot-swap). Ensure the system is configured to handle the state transition of field outputs to a safe condition before removing the module from the carrier.

Q: What is the purpose of the 16-pin mass termination block?

A: The 16-pin mass termination block facilitates rapid field wiring connection to the I/O module. It serves as the physical interface for all 8 discrete output channels, allowing for efficient cable management and consistent point-to-point electrical contact.

Field Installation Guidelines

  1. Mounting: Install the module onto the designated I/O carrier. Ensure the carrier is properly secured to the mounting rail and the backplane connector is aligned to prevent pin damage during insertion.
  2. Termination: Utilize the 16-pin mass termination block for field wiring. Strip wires to the manufacturer-specified length and secure them firmly in the terminal block to ensure low-resistance electrical contact.
  3. Grounding: Ensure the I/O carrier is bonded to a clean earth ground to maintain signal integrity and provide a path for surge suppression.
  4. Verification: After installation, utilize the system engineering station to perform a loop check. Confirm that the module diagnostics report clear channel status and that field devices respond according to the commanded output state.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more