Overview

The HIMA F2 DO 16 02/F2DO1602 is a safety-related remote output module engineered for high availability and robust performance in critical industrial automation systems. It is part of the HIMatrix F2 series and provides reliable SIL 3 performance for diverse safety applications. Designed for compact installation, this module supports streamlined communication and easy integration into existing control networks.

Technical Specifications

  • Manufacturer: HIMA

  • Model Number: F2 DO 16 02/F2DO1602

  • Product Type: Safety Controller Remote Output Module

  • Safety Integrity Level (SIL): 3

  • Number of Digital Inputs: 16

  • Number of Digital Outputs: 16

  • Communication Protocol: Modbus TCP/IP

  • Mounting: DIN rail

  • Dimensions (L × W × H): 25.3 × 11.6 × 10 cm

  • Weight: 2 kg

  • Key Features: Compact form factor, high availability, and wide safety application coverage

Key Features

  • Certified SIL 3 for maximum safety compliance

  • Supports 16 digital inputs and 16 digital outputs

  • Modbus TCP/IP communication for network integration

  • Compact DIN rail mounting for flexible installation

  • Designed for high reliability and continuous operation

Application Scenarios

The HIMA F2 DO 16 02 is suitable for:

  • Safety interlock and emergency shutdown systems

  • Process automation requiring remote output monitoring

  • Integration into HIMatrix F2 series safety networks

  • Industrial facilities demanding high system uptime and reliability

FAQ

Q: What safety standard does the F2DO1602 meet?
A: The module is SIL 3 certified, ensuring compliance with IEC 61508 safety standards.

Q: Can it communicate with existing Modbus networks?
A: Yes. The F2DO1602 supports Modbus TCP/IP for seamless integration into existing networks.

Q: What installation options are available?
A: It is designed for DIN rail mounting in standard control panels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more