Overview

The HIMA F3 DIO 8/8 01/F3DIO8/801 is a high-reliability digital input/output module engineered for HIMatrix safety systems. It combines SIL 3 certified safety performance with compact design, ensuring dependable operation in complex industrial automation environments. The module supports simultaneous digital input and output operations, enabling seamless integration in safety-critical applications.

Technical Specifications

  • Manufacturer: HIMA

  • Model Number: F3 DIO 8/8 01/F3DIO8/801

  • Product Type: Safety-Related Controller Module

  • Digital Inputs: 8

  • Digital Outputs: 8

  • Operating Voltage: 24 V DC

  • Power Consumption: 8 W

  • Operating Temperature Range: -20°C to +60°C

  • Storage Temperature Range: -40°C to +85°C

  • Dimensions: 156 × 77 × 113 mm

  • Weight: 0.7 kg

  • Protection Rating: IP20

  • Certifications: IEC 61508 compliant, SIL 3 certified

  • Communication Protocols: Ethernet, Modbus TCP/IP

  • Mounting: DIN rail

Key Features

  • Compact digital I/O module with 8 inputs and 8 outputs

  • Certified SIL 3 for high-level safety applications

  • Supports Ethernet and Modbus TCP/IP communication for integration

  • Rugged construction suitable for industrial environments

  • Efficient power consumption of only 8 W

Application Scenarios

  • Process Safety: Reliable monitoring and control in safety instrumented systems

  • Machine Safety: Emergency stop, interlocks, and protective devices

  • Building Automation: Safety monitoring in elevators, fire systems, and access controls

FAQ

Q: What certifications does the F3 DIO 8/8 01 hold?
A: It is SIL 3 certified and compliant with IEC 61508.

Q: What is the operating voltage and power consumption?
A: 24 V DC operating voltage with 8 W power usage.

Q: How is this module mounted?
A: Standard DIN rail mounting for easy installation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more