HC900 | Honeywell 900C72-0144-00 C70 CPU ModuleHC900 | Honeywell 900C72-0144-00 C70 CPU ModuleHC900 | Honeywell 900C72-0144-00 C70 CPU Module
HC900 | Honeywell 900C72-0144-00 C70 CPU Module
HC900 | Honeywell 900C72-0144-00 C70 CPU Module
HC900 | Honeywell 900C72-0144-00 C70 CPU Module

HC900 | Honeywell 900C72-0144-00 C70 CPU Module


Only 10 left - Selling fast

PRODUCT SKU : 900C72-0144-00

PRODUCT TYPE : CPU Processors

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 900C72-0144-00 serves as the primary 900C72-0144-00 Controller CPU Module utilized to execute real-time control algorithms and deterministically process up to 480 I/O points across Honeywell HC900 Process Control System platforms.

Hardware Specifications

Parameter Specification
Model 900C72-0144-00
Brand Honeywell
Origin USA
Weight 0.56 kg
Dimensions 3.0 cm x 31.3 cm x 27.8 cm
Operating Temp -20 to +60 deg C
Power Consumption 24 VDC nominal supply input
Processor Type Advanced 32-bit microcontroller
Memory Type Non-volatile memory for program and data storage
I/O Expansion Capacity Supports up to 480 I/O points
Integrated Interfaces Ethernet (10/100 Mbps), RS-485 serial, RS-232 serial
Engineering Software Honeywell HC Designer software
Control Logic Execution PID loops, discrete logic, sequencing, and timing functions

Channel-to-Channel Isolation and DCS Network Interoperability

Operating via a high-performance 32-bit microcontroller architecture, the 900C72-0144-00 CPU module governs multi-loop PID, timing, and sequential control operations across discrete and analog process racks. Integrated 10/100 Mbps Ethernet and RS-485/RS-232 serial interfaces establish deterministic data throughput to higher-level DCS host networks while maintaining loop signal integrity. Hardware-level channel-to-channel isolation prevents field ground loops and electrical transients from degrading 4-20 mA HART loop protocol signals and high-density I/O bus communications.

Frequently Asked Questions

Q: How does the non-volatile memory on the 900C72-0144-00 behave during a control rack power loss?

A: Program code and execution state parameters are stored in non-volatile flash memory, retaining full configuration data without requiring battery backup during prolonged power outages.

Q: What is the maximum physical I/O expansion capability supported by a single 900C72-0144-00 CPU?

A: The module directly manages and scans a total memory map of up to 480 I/O points across connected local and expansion racks.

Q: Which serial communication protocols are physically supported by the integrated interfaces?

A: The CPU module incorporates dedicated RS-232 and RS-485 physical serial ports for point-to-point interface connections and multi-drop field device networks.

Field Installation Guidelines

  1. Verify that the primary rack power feed is de-energized before mounting or removing the 900C72-0144-00 CPU module.
  2. Align the module housing with the subrack guide slots and push firmly until the rear edge connector latches fully into the backplane.
  3. Terminate Ethernet communication cables using shielded RJ-45 connectors, grounding the cable shield braid to the main panel enclosure earth bus.
  4. Wire the 24 VDC auxiliary power supply connections ensuring correct polarity and recommended wire gauge limits.
  5. Maintain a minimum 50 mm clearance around the module chassis top and bottom vents to facilitate natural thermal convection.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more
Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Industrial automation has evolved from a simple manufacturing tool into the operational backbone of high-risk sectors. Modern mining operations increasingly rely on advanced control systems, programmable logic controllers (PLCs), distributed control systems (DCS), and artificial intelligence to address deep-underground hazards. By replacing manual labor in high-risk zones, factory automation technologies protect personnel while significantly boosting operational throughput.

Read more