Overview

The IC697CPX928 is a high-performance floating-point CPU module from GE Fanuc for Series 90-70 PLCs. It offers fast Boolean processing, substantial I/O capacity, and advanced memory configuration for demanding industrial automation tasks.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Product Line: Series 90-70

  • Product Type: CPU Module

  • Part Number: IC697CPX928

  • Weight: 1.88 lbs (0.85 kg)

  • Microprocessor: 80486DX4

  • Clock Speed: 96 MHz

  • RAM: 6 MB

  • Flash Memory: 256 KB

  • Power Supply: 5 VDC

  • Current Draw: 3.1 A

  • Boolean Scan Rate: 0.4 µs per Boolean function

  • Discrete I/O Capacity: 12K points (any mix)

  • Analog I/O Capacity: 8K points

  • Communication Ports: 1 RS232, 2 RS485, 1 Factory Reset

  • Battery Backup: Lithium battery (IC697ACC701)

  • Serial Ports Total: 3

Key Features

  • High-speed Boolean execution with 0.4 µs per function.

  • Large memory support with 6 MB RAM and 256 KB Flash for program flexibility.

  • Floating-point CPU capable of handling up to 12K discrete I/O and 8K analog I/O.

  • Multiple communication interfaces allow RS232 and RS485 connectivity for networked PLC applications.

  • Compatible with all GE Fanuc 90-70 PLC systems.

Application Scenarios

  • Process control requiring high-speed calculation and floating-point operations.

  • PLC systems with extensive I/O configurations including mixed discrete and analog points.

  • Industrial automation setups that require robust serial communication for monitoring and control.

FAQ

Q: What PLC systems is the IC697CPX928 compatible with?
A: It is designed for GE Fanuc Series 90-70 PLCs.

Q: What type of battery does this CPU use?
A: The CPU uses a lithium battery, model IC697ACC701, for memory retention.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more