Bachmann MC212 CPU ModuleBachmann MC212 CPU ModuleBachmann MC212 CPU Module
Bachmann MC212 CPU Module
Bachmann MC212 CPU Module
Bachmann MC212 CPU Module

Bachmann MC212 CPU Module


Only 10 left - Selling fast

PRODUCT SKU : MC212

PRODUCT TYPE : CPU Processors

PRODUCT VENDOR : Bachmann


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for real-time logic execution in control platforms, the Bachmann MC212 (MC212 CPU Module) provides direct processing and deterministic control within M1 system networks.

Hardware Specifications

Parameter Specification
Model MC212
Brand Bachmann
Origin Austria
Weight 0.3 kg
Dimensions 98 mm x 110 mm x 35 mm
Operating Temp -25 deg C to +60 deg C
Power Consumption 24 VDC nominal
Processor 32-bit embedded, 400 MHz
RAM 64 MB DDR RAM
Flash Memory 32 MB onboard

Profinet / EtherNet/IP Deterministic Networks

The MC212 architecture supports high-speed, deterministic control cycles required for complex industrial automation tasks. To maintain cycle-time consistency, the module utilizes an integrated PLC runtime environment that facilitates strict task scheduling across network interfaces. Firmware flash compatibility is maintained through the M1 system software, ensuring that communication protocols (Ethernet, RS232) remain synchronized with the I/O subsystem. Users must ensure that backplane bus communication velocity settings are correctly aligned with the application requirements to prevent packet jitter or missed execution cycles within the deterministic control loop.

Frequently Asked Questions

Q: Does the MC212 module support hot-swapping during active system operation?

A: Hot-swapping capabilities are dependent on the specific M1 backplane configuration and system software settings. Consult the system manual for procedures regarding module removal to prevent bus communication errors.

Q: How is the module cooled during operation?

A: The MC212 utilizes a fanless, convection-cooled design. Proper vertical clearance and airflow around the DIN-rail or rack installation must be maintained to stay within the -25 deg C to +60 deg C operating temperature range.

Field Installation Guidelines

  1. Secure the module onto the DIN-rail or within the M1 rack, ensuring the mechanical locking mechanism is fully engaged to provide a robust ground connection to the chassis.
  2. Verify that the 24 VDC power supply is stabilized and filtered to minimize electrical noise, which can affect the high-frequency processor operation.
  3. Use shielded RJ45 cabling for the 10/100 Mbit/s Ethernet interfaces to protect against electromagnetic interference in industrial environments.
  4. When connecting via RS232, ensure that the cable length is kept to a minimum and properly terminated to avoid signal reflections.
  5. Perform an initial system check by verifying the module status LEDs on the front panel to confirm successful firmware initialization and operational status.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more